Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instruction; Overview; Technical Specifications - clage DSX Touch Kurzanleitung

E-komfortdurchlauferhitzer
Vorschau ausblenden Andere Handbücher für DSX Touch:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
DSX Touch

Installation instruction

1. Overview

When ordering spare parts, please always specify the appliance model and serial number.
EN
Pos.
Function
1
Bottom part incl. leakage sensor
2
Safety thermal cut-out (STB)
3
Thermal sensor
4
Non-return valve
5
Flow sensor
6
Heating element
Safety pressure cut-out (SDB)
7
Outlet pipe
8
Hot water connection
9
Screw-in nipples ½ inch
10
Grommet
11
Water splash protection sleeve
12
Wall bracket
13

2. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
Chosen capacity / current
Electrical connection
Min. required cable size
1)
Hot water (l/min)
2)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required spec. water resistance
Spec. electrical conductivity
Inlet temperature
Required flow rate to switch on
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
Transmission and receiving frequency range Wi-Fi
Transmission power Wi-Fi
Transmission and receiving frequency range Bluetooth
Transmission power Bluetooth
Radiation
Transmission range
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013.
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Electronically controlled depending on the desired temperature and cold water temperature
18 kW / 26 A
4.0 mm
2
9.2
6.8
2
in electrical connection from above.
(Fig. C1)
Pos.
Function
DSX Touch hood
14
Connecting pipe
15
Power circuit board cover
16
Servomotor electronics
17
Power circuit board
18
Transmission module
19
Servomotor
20
21
Connecting terminal
22
Touch display incl. control panel support
23
Inlet pipe
24
Fine filter
25
Cold water connection
26
Frame
DSX TOUCH
A *
)
18 kW..27 kW (26 A..39 A)
21 kW / 30 A
3~ / PE 380..415 V AC
4.0 mm
2
10.7
7.9
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90 mS/m
≤ 70 °C
1.5 l/min – automatic
0.2 bar at 2.5 l/min 1.3 bar at 9.0 l/min
20 – 60 °C [70 °C]
G ½ inch
4.5 kg
2.412 – 2.472 GHz (802.11b/g/n)
≤ 100 mW
2.4 – 2.4385 GHz
≤ 8 mW
undirected
10 meter incl. barrier
I
14
24 kW / 35 A
27 kW / 39 A
3~ / PE 400 V AC
6.0 mm
2
6.0 mm
12.3
9.0
®
3)
IP25
2
13.8
10.2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis