Störungsbeseitigung
SPN
FMI
DTC
Fehler
Beschreibung
3873
4
210F04
Analog Output 02
shorted to GND or
Circuit Open (broken
wire, terminal floating)
3948
9
6C0F09
J1939 PTODE
Message (PTO
Drive Engagement)
is missing or not
available
4041
0
C90F00
Indication of a critical
software (logic) failure.
(20ms ECU OS Task
Locked in an Endless
Loop)
4041
9
C90F09
Indication of a
critical resource
allocation issue. Task
restructuring required.
(20ms ECU OS Task
Timed out Prior to
Completion)
4041
16
C90F10
Indication of a critical
software (logic) failure.
(1000ms ECU OS Task
Locked in an Endless
Loop)
4206
2
6E1002
TSC1 Message
Counter indicates lost
Messages
4207
2
6F1002
TSC1 Message
Checksum wrong
524275
19
F3FFF3
RCM Message not
received or stopped
arriving
524276
13
F4FFED
MCM fuelmap to GVC
emission standard
calibration (02/23)
mismatched
524277
13
F5FFED
Super Structure Cabin
Mode ENABLE-State
ERROR
Seite 306
Fehler Behebung
Fault
location
Check wiring of associated pin.
Pin 3/06
Check parameters 09/04 (Selection)
and 09/10 (Fault Detection) for correct
configuration of output pin 3/06.
Run Service Routine (chapter 6.4,
routines 8 to 10):
– Analog Output Pin Under Software
Control: Start with Signal Parameter 6,
Frequency in Hz, Width in %
Check J1939 link connection
Check Parameter 01/108 (PTODE
Source Address SAE J1939)
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
Check CPC4 PT-CAN link connection.
Check RCM functionality / PT-CAN link
connection
Check parameter 02/24 (GVC Emission
Standard Conf) for correct setting.
Check CPC4 PT-CAN link connection.
Check if vehicle speed has plausible
value. Check park brake state. Check if
gearbox sends valid values for current
and selected gear. Check if CC is
deactivated.
Erstellt im: Mai 2020
®
SPN
FMI
524277
14
524277
19
524278
13
524278
14
524278
15
524279
2
524279
3
524279
4
524279
11
524279
18
Erstellt im: Mai 2020
®
DTC
Fehler
Fehler Behebung
Beschreibung
F5FFEE
Driving from
Check CPC4 PT-CAN link connection.
SuperStructure
Check engine mode. Check service
IMPLAUSIBLE
brake state. Check if gearbox sends valid
Condition
values for current and selected gear.
Check if CC is deactivated.
F5FFF3
Super Structure Cabin
Check CPC4 PT-CAN link connection.
Mode DISABLE-State
Check if vehicle speed has plausible
ERROR
value. Check park brake state. Check if
gearbox sends valid values for current
and selected gear. Check if CC is
deactivated.
F6FFED
2-Channel RAT
Check wiring of associated pins.
Accelerator Pedal
Check parameter 09/01 (1 9 FPO_02
Signal 1 Missing
Selection) and parameter 09/06 (4 12
FPO_01 Selection)
Check parameter 09/12 (4 12 FPO_01
Fault Detection) for correct configuration
of Fault Detection of pin 4/12 and
parameter 09/08 (1 9 FPO_02 Fault
Detection) for correct configuration
of Fault Detection of pin 1/09. Check
parameter 09/14 (1 9 FPO_02 Resistor
Enable) for pin 1/09 resistor activation.
F6FFEE
2-Channel RAT
Check wiring of associated pins.
Accelerator Pedal
Check parameter 09/01 (1 9 FPO_02
Signal 2 Missing
Selection) and parameter 09/06 (4 12
FPO_01 Selection)
Check parameter 09/12 (4 12 FPO_01
Fault Detection) for correct configuration
of Fault Detection of pin 4/12 and
parameter 09/08 (1 9 FPO_02 Fault
Detection) for correct configuration
of Fault Detection of pin 1/09. Check
parameter 09/14 (1 9 FPO_02 Resistor
Enable) for pin 1/09 resistor activation.
F6FFEF
RAT Accelerator pedal
Deviation between RAT Ch1 and Ch2 too
„in-range" fault.
high. Check RAT AP Sensor.
F7FFE2
Expansion tank
Check wiring of associated pins.
pressure sensor data
Check parameter 13/63 (3 04 AI_02
erratic
Selection) and parameter 13/64 (4 14
AI_03 Selection)
F7FFE3
Expansion tank
Check wiring of associated pins.
pressure sensor circuit
Check parameter 13/63 (3 04 AI_02
shorted to Ubat
Selection) and parameter 13/64 (4 14
AI_03 Selection)
F7FFE4
Expansion tank
Check wiring of associated pins.
pressure sensor circuit
Check parameter 13/63 (3 04 AI_02
shorted to GND
Selection) and parameter 13/64 (4 14
AI_03 Selection)
F7FFEB
Expansion Pressure
Inspect Expansion Pressure Tank for
Tank Pressure Set
leaks
Fault
F7FFF2
Expansion Pressure
Inspect Expansion Pressure Tank for
Tank Pressure Loss
leaks
Störungsbeseitigung
Fault
location
Pin 4/12
Pin 1/09
Pin 4/12
Pin 1/09
Pin 3/04
Pin 4/14
Pin 3/04
Pin 4/14
Pin 3/04
Pin 4/14