Störungsbeseitigung
SPN
FMI
DTC
Fehler
Beschreibung
702
5
BE0205
Digital Output 3/08
Open Circuit (broken
wire, terminal floating)
703
3
BF0203
Digital Output 3/09
Circuit shorted to Ubat
703
4
BF0204
Digital Output 3/09
Circuit shorted to GND
703
5
BF0205
Digital Output 3/09
Open Circuit (broken
wire, terminal floating)
704
3
C00203
Digital Output 4/07
Circuit shorted to Ubat
Seite 284
Fehler Behebung
Fault
location
Check wiring of associated pin
Pin 3/08
Check parameters 35/07 (Selection),
35/26 (Fault Detection) and 35/43
(Configuration) for correct configuration
of output pin 3/08
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 10
Check wiring of associated pin
Pin 3/09
Check parameters 35/08 (Selection),
35/27 (Fault Detection) and 35/44
(Configuration) for correct configuration
of output pin 3/09
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 14
Check wiring of associated pin
Pin 3/09
Check parameters 35/08 (Selection),
35/27 (Fault Detection) and 35/44
(Configuration) for correct configuration
of output pin 3/09
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 14
Check wiring of associated pin
Pin 3/09
Check parameters 35/08 (Selection),
35/27 (Fault Detection) and 35/44
(Configuration) for correct configuration
of output pin 3/09
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 14
Check wiring of associated pin
Pin 4/07
Check parameters 35/16 (Selection),
35/35 (Fault Detection) and 35/52
(Configuration) for correct configuration
of output pin 4/07
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 15
Erstellt im: Mai 2020
®
SPN
FMI
704
4
704
5
705
3
705
4
705
5
Erstellt im: Mai 2020
®
DTC
Fehler
Fehler Behebung
Beschreibung
C00204
Digital Output 4/07
Check wiring of associated pin
Circuit shorted to GND
Check parameters 35/16 (Selection),
35/35 (Fault Detection) and 35/52
(Configuration) for correct configuration
of output pin 4/07
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Dvigital Output Pin Under Software
Control: Start Response with Signal
Parameter 15
C00205
Digital Output 4/07
Check wiring of associated pin
Open Circuit (broken
Check parameters 35/16 (Selection),
wire, terminal floating)
35/35 (Fault Detection) and 35/52
(Configuration) for correct configuration
of output pin 4/07
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 15
C10203
Digital Output 1/13
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 35/03 (Selection),
35/22 (Fault Detection) and 35/40
(Configuration) for correct configuration
of output pin 1/13
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 1
C10204
Digital Output 1/13
Check wiring of associated pin
Circuit shorted to GND
Check parameters 35/03 (Selection),
35/22 (Fault Detection) and 35/40
(Configuration) for correct configuration
of output pin 1/13
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 1
C10205
Digital Output 1/13
Check wiring of associated pin
Open Circuit (broken
Check parameters 35/03 (Selection),
wire, terminal floating)
35/22 (Fault Detection) and 35/40
(Configuration) for correct configuration
of output pin 1/13
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 1
Störungsbeseitigung
Fault
location
Pin 4/07
Pin 4/07
Pin 1/13
Pin 1/13
Pin 1/13
Seite 285