Herunterladen Inhalt Inhalt Diese Seite drucken

DAMMANN DT 2800H S4 Original Bedienungsanleitung Seite 167

Vorschau ausblenden Andere Handbücher für DT 2800H S4:
Inhaltsverzeichnis

Werbung

Störungsbeseitigung
SPN
FMI
DTC
Fehler
Beschreibung
2646
3
560A03
Digital Output 4/02
Circuit shorted to Ubat
2646
4
560A04
Digital Output 4/02
Circuit shorted to GND
2646
5
560A05
Digital Output 4/02
Open Circuit (broken
wire, terminal floating)
Off-Highway Engine
2882
13
420B0D
Configuration Selection
message on J1939
was not received or
has stopped arriving.
2900
9
540B09
J1939 ETC7 Message
is missing or not
available
3187
9
730C09
Transmission Shift
Console Datalink (LIN)
3353
2
190D02
Generator (Charging
System) D+ terminal
failure
3510
4
B60D04
Accelerator Pedal
Supply Voltage Circuit
shorted to GND
3510
7
B60D07
Accelerator Pedal
Supply Voltage Circuit
shorted to Ubat
3511
3
B70D03
Remote Accelerator
Pedal Supply Voltage
circuit shorted to Ubat
Seite 298
Fehler Behebung
Fault
location
Check wiring of associated pin
Pin 4/02
Check parameters 35/14 (Selection),
35/33 (Fault Detection) and 35/50
(Configuration) for correct configuration
of output pin 4/02
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 9
Check wiring of associated pin
Pin 4/02
Check parameters 35/14 (Selection),
35/33 (Fault Detection) and 35/50
(Configuration) for correct configuration
of output pin 4/02
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 9
Check wiring of associated pin
Pin 4/02
Check parameters 35/14 (Selection),
35/33 (Fault Detection) and 35/50
(Configuration) for correct configuration
of output pin 4/02
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 9
Check the J1939 link connection
Check parameter 01/72 for configuration
of OHECS source address
Check parameter 05/06 for proper
configuration
Check J1939 link connection to
Transmission Controller / Check if
Electronic Transmission Controller is
CAN capable
Check LIN wiring / stalk switch
Check wiring of Generator Terminal D+
or check Generator functionality
Check wiring of associated pins
Pin 1/08
Pin 3/03
Check wiring of associated pins
Pin 1/08
Pin 3/03
Check wiring of associated pins
Pin 3/03
(Supply)
Pin 3/02
(GND)
Erstellt im: Mai 2020
®
SPN
FMI
3511
4
3606
9
3645
9
3695
9
3695
13
3695
14
3695
19
3696
4
3696
9
3696
13
3696
14
3696
19
Erstellt im: Mai 2020
®
DTC
Fehler
Fehler Behebung
Beschreibung
B70D04
Remote Accelerator
Check wiring of associated pins
Pedal Supply Voltage
circuit shorted to GND
160E09
J1939 PROP04
Check J1939 link connection to Diesel
Message is missing or
Particulate Filter
not available
3D0E09
J1939 TCI Message
Check J1939 link connection
(Transfer Case
Information) is missing
6F0E09
J1939 DPF Regen
Check J1939 link connection to Diesel
Inhibit MUX Switch
Particulate Filter.
Message Stopped
Check Parameter 46/10 (DPF J1939
Arriving
Inhibt Sw Enable) and 46/11 (DPF J1939
Regen Sw Enable).
6F0E0D
J1939 DPF Regen
Check J1939 link connection to Diesel
Inhibit MUX Switch
Particulate Filter.
Message Contains
Check Parameter 46/10 (DPF J1939
SNV(SNA) Indicator
Inhibt Sw Enable) and 46/11 (DPF J1939
Regen Sw Enable).
6F0E0E
J1939 DPF Regen
Check J1939 link connection to Diesel
Inhibit MUX Switch
Particulate Filter.
Message Not Received
Check Parameter 46/10 (DPF J1939
this Ignition Cycle
Inhibt Sw Enable) and 46/11 (DPF J1939
Regen Sw Enable).
6F0E13
J1939 DPF Regen
Check J1939 link connection to Diesel
Inhibit MUX Switch
Particulate Filter.
Message Contains
Check Parameter 46/10 (DPF J1939
Data Error(erractic)
Inhibt Sw Enable) and 46/11 (DPF J1939
Indicator
Regen Sw Enable).
700E04
J1939 DPF
Check J1939 link connection to Diesel
Regeneration Switch
Particulate Filter.
Circuit shorted to GND
Check Parameter 46/10 (DPF J1939
(if applied more than 5
Inhibt Sw Enable) and 46/11 (DPF J1939
sec this error flags)
Regen Sw Enable).
700E09
J1939 DPF Regen
Check J1939 link connection to Diesel
Force MUX Switch
Particulate Filter.
Message Stopped
Check Parameter 46/10 (DPF J1939
Arriving
Inhibt Sw Enable) and 46/11 (DPF J1939
Regen Sw Enable).
700E0D
J1939 DPF Regen
Check J1939 link connection to Diesel
Force MUX Switch
Particulate Filter.
Message Contains
Check Parameter 46/10 (DPF J1939
SNV(SNA) Indicator
Inhibt Sw Enable) and 46/11 (DPF J1939
Regen Sw Enable).
700E0E
J1939 DPF Regen
Check J1939 link connection to Diesel
Force MUX Switch
Particulate Filter.
Message Not Received
Check Parameter 46/10 (DPF J1939
this Ignition Cycle
Inhibt Sw Enable) and 46/11 (DPF J1939
Regen Sw Enable).
700E13
J1939 DPF Regen
Check J1939 link connection to Diesel
Force MUX Switch
Particulate Filter.
Message Contains
Check Parameter 46/10 (DPF J1939
Data Error(erractic)
Inhibt Sw Enable) and 46/11 (DPF J1939
Indicator
Regen Sw Enable).
Störungsbeseitigung
Fault
location
Pin 3/03
(Supply)
Pin 3/02
(GND)
Seite 299

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für DAMMANN DT 2800H S4

Diese Anleitung auch für:

Dt 2800h s5Dt 3500h s4Dt 3500h s5Dt 2400h s4Dt 3500h s5 highlander

Inhaltsverzeichnis