Herunterladen Inhalt Inhalt Diese Seite drucken

DAMMANN DT 2800H S4 Original Bedienungsanleitung Seite 159

Vorschau ausblenden Andere Handbücher für DT 2800H S4:
Inhaltsverzeichnis

Werbung

Störungsbeseitigung
SPN
FMI
DTC
Fehler
Beschreibung
625
14
71020E
PTCAN: MCM Sytem
ID Not Received or
Stopped Arriving
(ECAN ID_596/7 not
received or it has
stopped arriving)
628
2
740202
EEPROM Checksum
Failure
628
12
74020C
EEPROM Checksum
Failure for the SCR
Block
628
14
74020E
XFLASH Static Fault
Code Memory Page
Read Write Failure
(XFLASH Failure.)
628
17
740211
1000ms ECU OS Task
Timed out Prior to
Completion. (Indication
of a critical resource
allocation issue. Task
restructuring required.)
629
2
750202
CPC Hardware /
Software Mismatch
(Incorrect Hardware
Configuration - NAFTA
Vs. EUROPE)
DDEC Data Xflash
629
12
75020C
Write Error. Replace
CPC. (XFLASH
Failure.)
630
13
76020D
SCR Number out Of
Range
639
9
7F0209
J1939 PROP11
message no longer
received within it's
expected time.
639
13
7F020D
HDMS Fan is
configured and the
J1939 message was
not received or has
stopped arriving.
639
14
7F020E
J1939 Data Link
Failure (CPC is no
longer sending or
receiving data from the
J1939 link.)
667
3
9B0203
Starter Pin 1/18 Circuit
shorted to Ubat (KL50)
Seite 282
Fehler Behebung
Fault
location
Check PT-CAN link connection.
Check MCM functionality / PT-CAN link
connection
Try reprogramming the CPC with the
new software release. Reset EEPROM
values to default. Redownload CPC
parameter set.
Replace CPC4 and reprogram with the
latest software.
FUSO only. None. To be checked
PEP. Replace modul if this failure occurs
again.
Replace CPC4 box due to XFLASH
failure and reprogram with the latest
software.
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
Try reprogramming the CPC with the
new software release. Reset EEPROM
values to default. Redownload CPC
parameter set.
Replace CPC4 and reprogram with the
latest software.
Try reprogramming the CPC with the
new software release.
Replace CPC4 and reprogram with the
latest software.
FUSO only. Reset EEPROM values to
default. Redownload CPC.
Use SPN default values. SA
Parameter
01/17 (FUSO ISS Source Addr SAE
J1939)
Check J1939 link connection to the air
conditioner transducer. Check if CPC4
parameters correct for the vehicle
configuration.
Check J1939 data link connection
Pin 2/16
Pin 2/17
Pin 2/18
Check KL50 wiring at Pin 1/18
Pin 1/18
Erstellt im: Mai 2020
®
SPN
FMI
701
3
701
4
701
5
702
3
702
4
Erstellt im: Mai 2020
®
DTC
Fehler
Fehler Behebung
Beschreibung
BD0203
Digital Output 3/07
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 35/06 (Selection),
35/25 (Fault Detection) and 35/42
(Configuration) for correct configuration
of output pin 3/07
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 9
BD0204
Digital Output 3/07
Check wiring of associated pin
Circuit shorted to GND
Check parameters 35/06 (Selection),
35/25 (Fault Detection) and 35/42
(Configuration) for correct configuration
of output pin 3/07
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 9
BD0205
Digital Output 3/07
Check wiring of associated pin
Open Circuit (broken
Check parameters 35/06 (Selection),
wire, terminal floating)
35/25 (Fault Detection) and 35/42
(Configuration) for correct configuration
of output pin 3/07
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 9
BE0203
Digital Output 3/08
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 35/07 (Selection),
35/26 (Fault Detection) and 35/43
(Configuration) for correct configuration
of output pin 3/08
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 10
BE0204
Digital Output 3/08
Check wiring of associated pin
Circuit shorted to GND
Check parameters 35/07 (Selection),
35/26 (Fault Detection) and 35/43
(Configuration) for correct configuration
of output pin 3/08
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 10
Störungsbeseitigung
Fault
location
Pin 3/07
Pin 3/07
Pin 3/07
Pin 3/08
Pin 3/08
Seite 283

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für DAMMANN DT 2800H S4

Diese Anleitung auch für:

Dt 2800h s5Dt 3500h s4Dt 3500h s5Dt 2400h s4Dt 3500h s5 highlander

Inhaltsverzeichnis