Störungsbeseitigung
SPN
FMI
DTC
Fehler
Beschreibung
924
4
9C0304
Digital Output 4/09
Circuit shorted to GND
924
5
9C0305
Digital Output 4/09
Open Circuit (broken
wire, terminal floating)
925
3
9D0303
Digital Output 3/17
Circuit shorted to Ubat
925
4
9D0304
Digital Output 3/17
Circuit shorted to GND
925
5
9D0305
Digital Output 3/17
Open Circuit (broken
wire, terminal floating)
Seite 292
Fehler Behebung
Fault
location
Check wiring of associated pin
Pin 4/09
Check parameters 35/17 (Selection),
35/36 (Fault Detection) and 35/53
(Configuration) for correct configuration
of output pin 4/09
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 7
Check wiring of associated pin
Pin 4/09
Check parameters 35/17 (Selection),
35/36 (Fault Detection) and 35/53
(Configuration) for correct configuration
of output pin 4/09
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 7
Check wiring of associated pin
Pin 3/17
Check parameters 35/12 (Selection),
35/31 (Fault Detection) and 35/48
(Configuration) for correct configuration
of output pin 3/17
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 8
Check wiring of associated pin
Pin 3/17
Check parameters 35/12 (Selection),
35/31 (Fault Detection) and 35/48
(Configuration) for correct configuration
of output pin 3/17
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 8
Check wiring of associated pin
Pin 3/17
Check parameters 35/12 (Selection),
35/31 (Fault Detection) and 35/48
(Configuration) for correct configuration
of output pin 3/17
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 8
Erstellt im: Mai 2020
®
SPN
FMI
926
3
926
4
926
5
970
3
970
4
972
2
973
2
973
9
973
13
Erstellt im: Mai 2020
®
DTC
Fehler
Fehler Behebung
Beschreibung
9E0303
Digital Output 4/01
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 35/13 (Selection),
35/32 (Fault Detection) and 35/49
(Configuration) for correct configuration
of output pin 4/01
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 16
9E0304
Digital Output 4/01
Check wiring of associated pin
Circuit shorted to GND
Check parameters 35/13 (Selection),
35/32 (Fault Detection) and 35/49
(Configuration) for correct configuration
of output pin 4/01
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 16
9E0305
Digital Output 4/01
Check wiring of associated pin
Open Circuit (broken
Check parameters 35/13 (Selection),
wire, terminal floating)
35/32 (Fault Detection) and 35/49
(Configuration) for correct configuration
of output pin 4/01
Run Service Routine (chapter 6.4,
routines 15 to 17):
– Digital Output Pin Under Software
Control: Start Response with Signal
Parameter 16
CA0303
Engine Aux. Shutdown
Check wiring of associated pin.
Input shorted to Ubat
Check parameters 13/03 (Selection)
and 13/35 (Fault Detection) for correct
configuration of input pin 1/01.
CA0304
Engine Aux. Shutdown
Check wiring of associated pin.
Input shorted to GND
Check parameters 13/03 (Selection)
and 13/35 (Fault Detection) for correct
configuration of input pin 1/01.
CC0302
Throttle inhibit switch
Check wiring of associated pin.
signal not plausible
Check parameters 13/05 (Selection)
due to excess vehicle
and 13/43 (Fault Detection) for correct
configuration of input pin 1/17.
speed
CD0302
Evobus 5stage
Check wiring of associated pin.
retarder level position
Check parameters 13/08 (Selection)
not plausible
and 13/49 (Fault Detection) for correct
configuration of input pin 2/13.
CD0309
J1939 EBC1 Message
Check J1939 link connection and
is missing or not
Devices Turbocharger.
available
Check Parameter 01/10 (EBC1 Source
Adress SAE J1939)
CD030D
J1939 Engine
Check J1939 link connection to Engine
Retarder Selection
Retarder
Signal Missing or not
available = SNA (signal
not available)
Störungsbeseitigung
Fault
location
Pin 4/01
Pin 4/01
Pin 4/01
Pin 1/10
Pin 1/10
Pin 1/17
Pin 2/13
Seite 293