Störungsbeseitigung
SPN
FMI
DTC
Fehler
Beschreibung
3719
0
870E00
DPF Filter Soot Level
is very high
3719
16
870E10
DPF Filter Soot Level
is High
3840
3
000F03
Frequency Output 4/15
Circuit shorted to Ubat
3840
4
000F04
Frequency Output 4/15
Circuit shorted to GND
3840
5
000F05
Frequency Output 4/15
Open Circuit (broken
wire, terminal floating)
3841
3
010F03
Frequency Output 4/11
Circuit shorted to Ubat
3841
4
010F04
Frequency Output 4/11
Circuit shorted to GND
3841
5
010F05
Frequency Output 4/11
Open Circuit (broken
wire, terminal floating)
3842
3
020F03
Analog Ground 3/02
Circuit shorted to Ubat
3842
4
020F04
Analog Ground 3/02
Circuit shorted to GND
3842
5
020F05
Analog Ground 3/02
Open Circuit (broken
wire, terminal floating)
3843
3
030F03
Digital Input 1/01
Circuit shorted to Ubat
3843
4
030F04
Digital Input 1/01
Circuit shorted to GND
Seite 300
Fehler Behebung
Fault
location
Check DPF Filter.
Check DPF Filter. Start manual
regeneration.
Check wiring of associated pin.
Pin 4/15
Check Parameters 09/07 (Selection),
09/13 (Fault Detection) and 09/17
(Output Configuration) for correct
configuration.
Check wiring of associated pin.
Pin 4/15
Check Parameters 09/07 (Selection),
09/13 (Fault Detection) and 09/17
(Output Configuration) for correct
configuration.
Check wiring of associated pin.
Pin 4/15
Check Parameters 09/07 (Selection),
09/13 (Fault Detection) and 09/17
(Output Configuration) for correct
configuration.
Check wiring of associated pin.
Pin 4/11
Check Parameters 09/07 (Selection),
09/13 (Fault Detection) and 09/17
(Output Configuration) for correct
configuration.
Check wiring of associated pin.
Pin 4/11
Check Parameters 09/07 (Selection),
09/13 (Fault Detection) and 09/17
(Output Configuration) for correct
configuration.
Check wiring of associated pin.
Pin 4/11
Check Parameters 09/07 (Selection),
09/13 (Fault Detection) and 09/17
(Output Configuration) for correct
configuration.
Check wiring of associated pin
Pin 3/02
Check Parameters 35/05 (Selection)
and 35/24 (Fault Detection) for correct
configuration.
Check wiring of associated pin
Pin 3/02
Check Parameters 35/05 (Selection)
and 35/24 (Fault Detection) for correct
configuration.
Check wiring of associated pin
Pin 3/02
Check Parameters 35/05 (Selection)
and 35/24 (Fault Detection) for correct
configuration.
Check wiring of associated pin
Pin 1/01
Check parameters 13/01 (Selection),
13/35 (Fault Detect Ena) for correct
configuration of input pin 1/01
Check wiring of associated pin
Pin 1/01
Check parameters 13/01 (Selection),
13/35 (Fault Detect Ena) for correct
configuration of input pin 1/01
Erstellt im: Mai 2020
®
SPN
FMI
3844
3
3844
4
3845
3
3845
4
3846
3
3846
4
3847
3
3847
4
3848
3
3848
4
3849
3
3849
4
3850
3
Erstellt im: Mai 2020
®
DTC
Fehler
Fehler Behebung
Beschreibung
040F03
Digital Input 1/02
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 13/01 (Selection),
13/35 (Fault Detect Ena) for correct
configuration of input pin 1/02
040F04
Digital Input 1/02
Check wiring of associated pin
Circuit shorted to GND
Check parameters 13/02 (Selection),
13/36 (Fault Detect Ena) for correct
configuration of input pin 1/02
050F03
Digital Input 1/12
Check wiring of associated pin
Circuit shorted to Ubat
Check parameter 13/39 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/12
050F04
Digital Input 1/12
Check wiring of associated pin
Circuit shorted to GND
Check parameter 13/39 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/12
060F03
Digital Input 1/14
Check wiring of associated pin
Circuit shorted to Ubat
Check parameter 13/40 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/12
060F04
Digital Input 1/14
Check wiring of associated pin
Circuit shorted to GND
Check parameter 13/40 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/12
070F03
Digital Input 1/15
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 13/04 (Selection),
13/41 (Fault Detect Ena) for correct
configuration of input pin 1/15
070F04
Digital Input 1/15
Check wiring of associated pin
Circuit shorted to GND
Check parameters 13/04 (Selection),
13/41 (Fault Detect Ena) for correct
configuration of input pin 1/15
080F03
Digital Input 1/16
Check wiring of associated pin
Circuit shorted to Ubat
Check parameter 13/42 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/16
080F04
Digital Input 1/16
Check wiring of associated pin
Circuit shorted to GND
Check parameter 13/42 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/16
090F03
Digital Input 1/17
Check wiring of associated pin
Circuit shorted to Ubat
Check parameters 13/05 (Selection),
13/43 (Fault Detect Ena) for correct
configuration of input pin 1/17
090F04
Digital Input 1/17
Check wiring of associated pin
Circuit shorted to GND
Check parameters 13/05 (Selection),
13/43 (Fault Detect Ena) for correct
configuration of input pin 1/17
0A0F03
Digital Input 1/11
Check wiring of associated pin
Circuit shorted to Ubat
Check parameter 13/38 (Fault Detect
Ena) for correct configuration of Fault
Detection of pin 1/11
Störungsbeseitigung
Fault
location
Pin 1/02
Pin 1/02
Pin 1/12
Pin 1/12
Pin 1/14
Pin 1/14
Pin 1/15
Pin 1/15
Pin 1/16
Pin 1/16
Pin 1/17
Pin 1/17
Pin 1/11