Remove the steel cables and dismantle the torsion springs.
Secure horizontal track pairs against falling.
(35)
(36)
Remove the 89°arcs.
(37)
Unscrew and remove the fastening of the horizontal track
pairs from the ceiling and walls.
Fold the horizontal track pairs and unscrew them from the
(38)
door frame.
(39)
Dismantle anchor tracks.
(40)
Unscrew the horizontal track pairs from the track connector.
(41)
Section by section, working from the top down, dismantle
the rollers and hinges and remove each section from the
door.
(42)
Secure the door frame against falling. Unscrew the wall
and floor fastenings, carry the door frame out of the opening,
place it on the ground and dismantle it (in reverse order
compared to installation).
Operating and maintenance instructions for
sectional doors
Types iso70-1, with (front mounted [VL] or rear
mounted [HL]) torsion spring
Incorrect
operation
manufacturer's liability null and void, as does failure to use
original spare parts or making any unauthorised changes
to the structure of the door. This garage door is designed
for private use. If used commercially, compliance with
corresponding national and international regulations is
mandatory.
Operation:
The mechanical equipment of this door is designed to mitigate
to the greatest possible extent the risk of anyone operating or
standing near the door being crushed, cut, clipped or otherwise
injured. To ensure safe use of the door, the following points
must be observed:
 Before and during the cycle make sure that there are no
persons or objects, except for the operator, within range of
moving parts (e.g. door leaf, rollers, etc.).
 Manual operation of the sectional garage door is only
permissible using the outdoor or indoor handles, or the hand
pull. Operators must not interfere with moving parts.
 Lock function
‒ Turning the key fully enables the sectional garage door
to be opened and closed without a key at all times.
‒ Turn the key 3/4 to open the door and back the other
way 3/4 to lock it when closed.
‒ The inside unlocking/locking knob can be activated to
enable opening and closing without a key.
 Keep people and objects out of opening range when
operating the sectional garage door from inside or out.
 When opening, push the door leaf to its in end position and
wait until it has come to a standstill before taking any other
action. Sufficient spring tension must be present.
Caution: The spring tension may only be adjusted by a
qualified installer!
Operation of this door is only permissible at temperatures
between -20°C and +40°C.
 The A-weighting sound pressure level is less than 70dB.
 Make sure the catch engages securely when closing the
sectional garage door.
 When equipping this door with an operator,
Keep these installation, operating, and maintenance instructions in a safe place during the entire service life of the garage door!
or
maintenance
renders
‒ the system must comply with all applicable EU Directives
(Machinery, Low Voltage, EMC Directives, etc.), as well
as with all applicable national and international norms
and regulations
‒ the system must be duly fitted with a type plate and CE
mark by the manufacture, and a declaration of
performance must have been issued
‒ handover literature must be available in the local
language and must be kept in a safe place throughout
the service life of the garage door
‒ the lock (catch, staple plate) must be dismantled.
Removal of the hand pull is absolutely essential!
Adjustments to the garage door operator may only be
performed by appropriately qualified installers!
 When equipping this door with a pass door:
The pass door is in safe position when the lock's catch is
fully engaged in the edge plate.
Maintenance:
The following must be checked following installation of the
garage door and every 6 months thereafter, at least.
Maintenance by unskilled or suitably qualified installers:
the
 Grease the roller axes in the holders and clean the
horizontal track pairs once installation of the sectional
garage door is complete and at intervals of approx. 5,000
cycles.
 Do not grease the lock cylinder; if it does not run smoothly
enough, treat it with graphite spray.
 Ensure sufficient ventilation (drying) of the door frame; water
drainage must also be ensured.
 Keep all corrosives or other aggressive agents such as
acids, lyes, salts, etc. away from the sectional garage door.
Only use mild household detergent to clean the door.
 Steel-filled sectional garage doors are coated with polyester
at the factory. Any paintwork on site must be applied within
3 months from delivery using 2C epoxy primer containing
solvents and, once hardened, standard paint.
 Touch up the paint at intervals as required by local
environmental and atmospheric conditions.
 We recommend wiping the door regularly with a soft, damp
cloth. If necessary, use a mild cleaning agent or soap with
lukewarm water. Avoid using any polishing agents or
abrasive or organic solvents/cleaning agents. Before
cleaning, flush the door and glazing thoroughly with water to
avoid scratches caused by dust particles.
Maintenance by suitably qualified installers:
 Check the door according to the inspection instructions.
 Check screws and clamp connections for secure fit and
tighten if necessary.
 Check wearing parts (springs, steel cables, etc.) and
replace with original spare parts, if necessary.
 Check that the spring tension is correct. If the spring tension
needs adjusting, proceed according to the installation
instructions.
 Replace the torsion springs and cables after approx. 25,000
cycles (open/close).
This is necessary:
0 – 5 Door operations per day
6 – 10
11 – 20
- 12 -
all
14 years
"
"
7 years
"
"
3.5 years