1 Bit
780, 807
1 Bit
1 Bit
781, 808
1 Bit
1 Bit
782, 809
1 Bit
1 Bit
783, 810
1 Bit
784, 811
1 Bit
785, 812
1 Bit
786, 813
1 Byte
2 Bytes
787, 814
2 Bytes
788, 815
1 Bit
789, 816
2 Bytes
790, 817
2 Bytes
791, 818
2 Bytes
792, 819
2 Bytes
1 Bit
793, 820
1 Bit
794, 821
1 Bit
795, 822
1 Bit
796, 823
1 Bit
797, 824
1 Bit
1 Bit
798, 825
1 Bit
1 Bit
799, 826
1 Bit
800, 827
1 Byte
801, 828
1 Byte
802, 829
1 Bit
803, 830
1 Bit
831, 837
1 Bit
832, 838
1 Bit
http://www.zennio.com
I
C - - W -
DPT_Trigger
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Trigger
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Trigger
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Trigger
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Window_Door
I
C - - W -
DPT_Trigger
O
C T R - -
DPT_HVACMode
I
C - - W -
DPT_Value_Temp
I
C - - W -
DPT_Value_Temp
I
C - - W -
DPT_Step
I
C - - W -
DPT_Value_Tempd
O
C T R - -
DPT_Value_Temp
O
C T R - -
DPT_Value_Temp
O
C T R - -
DPT_Value_Tempd
I
C - - W -
DPT_Reset
I
C - - W -
DPT_Reset
I
C - - W -
DPT_Heat_Cool
O
C T R - -
DPT_Heat_Cool
I
C - - W -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Scaling
O
C T R - -
DPT_Scaling
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
I
C - - W -
DPT_Switch
C T - - -
DPT_Switch
2 = Standby
3 = Economy
4 = Protection
0/1
[T1] Special Mode: Komfort
0/1
[T1] Special Mode: Komfort
0/1
[T1] Special Mode: Standby
[T1] Special Mode: Standby
0/1
0/1
[T1] Special Mode: Nacht/Eco
0/1
[T1] Special Mode: Nacht/Eco
0/1
[T1] Special Mode: Frostschutz
0/1
[T1] Special Mode: Frostschutz
0/1
[T1] Window Status (Input)
[T1] Comfort Prolongation
0/1
1 = Comfort
2 = Standby
[T1] Special Mode Status
3 = Economy
4 = Protection
-273,00 - 670760,00
[T1] Setpoint
-273.00 - 670760.00
[T1] Basic Setpoint
0/1
[T1] Setpoint Step
-670760.00 - 670760.00 [T1] Setpoint Offset
-273.00 - 670760.00
[T1] Setpoint Status
-273.00 - 670760.00
[T1] Basic Setpoint Status
-670760.00 - 670760.00 [T1] Setpoint Offset Status
0/1
[T1] Setpoint Reset
0/1
[T1] Offset Reset
[T1] Mode
0/1
0/1
[T1] Mode Status
0/1
[T1] On/Off
[T1] On/Off Status
0/1
0/1
[T1] Control Variable (Cool)
0/1
[T1] Control Variable (Cool)
0/1
[T1] Control Variable (Heat)
0/1
[T1] Control Variable (Heat)
0% - 100%
[T1] Control Variable (Cool)
0% - 100%
[T1] Control Variable (Heat)
0/1
[T1] Additional Cool
0/1
[T1] Additional Heat
0/1
[I1] Input Lock
0/1
[I1] [Short Press] 0
Z41 Pro / Z41 Lite
0=Nothing; 1=Trigger
0=Off; 1=On
0=Nothing; 1=Trigger
0=Off; 1=On
0=Nothing; 1=Trigger
0=Off; 1=On
0=Nothing; 1=Trigger
0=Off; 1=On
0=Closed; 1=Open
0=Nothing; 1=Timed Comfort
1-byte HVAC Mode
Thermostat Setpoint Input
Reference Setpoint
0=-0.5ºC; 1=+0.5ºC
Float Offset Value
Current Setpoint
Current Basic Setpoint
Current Setpoint Offset
Reset Setpoint to Default
Reset Offset
0=Cool; 1=Heat
0=Cool; 1=Heat
0=Off; 1=On
0=Off; 1=On
2-Point Control
PI Control (PWM)
2-Point Control
PI Control (PWM)
PI Control (Continuous)
PI Control (Continuous)
Temp >= (Setpoint+Band) => "1"
Temp <= (Setpoint-Band) => "1"
1 = Locked; 0 = Unlocked
Sending of 0
Technischer Support:
http://support.zennio.com
106