7. Description of program numbers

7.3.2 Reference value

The reference value is the value which is given via the analogue output.
PN
Function
EN
22
Reference value

7.3.3 Output signal

PN
Function
23
Output signal
Example
A rotational speed of 0 ... 3,000 min-1 should be transmitted to a control room via
4 ... 20 mA. The rotational speed sensor is connected to measuring input 1.
1. Set the end value to 3,000.
2. Set the start value to 0.
3. Set the reference value to 1.
4. Set the output signal to 2.
5. Set the DIP switch.
Analogue output is set.
32
In addition, the output signal must be set via the DIP switch on the rear of
the instrument.
DC 0 ... 10 V = switch set to the right
0/4 ... 20 mA = switch set to the left
WIKA operating instructions digital indicator, model DI35-M
Parameter
0 = analogue output deactivated
1 = instantaneous value
2 = MIN value
3 = MAX value
4 = HOLD value
5 = running average
6 = totaliser value
7 = absolute value
Parameter
0 = DC 0 ... 10 V
1 = 0 ... 20 mA
2 = 4 ... 20 mA