7. Description of program numbers
Mode
Instantaneous value
MIN value
EN
MAX Value
Running average
Totaliser value
Absolute value
Trigger mode

7.2.5 Trigger for MIN/MAX reset

The value reset is only signalised briefly, following the actuation of the digital input or the
multi-function button by 5 dashes ("- - - - - "). If the reset is made via the taring, this is not
signalled.
With the reset, only the MIN/MAX value currently visible in the digital display is reset.
PN
Function
16
Trigger for MIN/MAX reset
30
Description
The last value measured is displayed.
The smallest display value occurring since the last MIN reset is
displayed. The MIN reset is triggered according to the configuration
(→ see chapter 7.2.5 "Trigger for MIN/MAX reset").
The largest display value occurring since the last MAX reset is
displayed. The MAX reset is triggered according to the configuration
(→ see chapter 7.2.5 "Trigger for MIN/MAX reset").
The running average is displayed. The total averaging time is given
from the multiplication of the measuring time (PN14) and the regis-
tered averaging value (PN12).
The totaliser value is displayed
The value measured since the power supply was connected,
without calculation of a prior taring, is displayed.
The instantaneous value is only updated by a rising edge via the
digital input.
Following the reset, in the "MIN/MAX value" display mode, the instantane-
ous value is displayed until the trigger is reset. This allows the instantane-
ous value to be observed for an extended period of time.
WIKA operating instructions digital indicator, model DI35-M
Parameter
0 = no trigger
1 = digital input
2 = multi-function button
3 = digital input or multi-function
button
4 = on taring