7. Description of program numbers

7. Description of program numbers
For an overview of the program numbers see "Appendix 1: Overview of program numbers"

7.1 Setting the measuring input

7.1.1 Input signal

The digital indicator has a multi-function input, which can be used for a variety of input
signals.
PN
Function
0
Input signal
WIKA operating instructions digital indicator, model DI35-M
Parameter
Current
01 = 0 ... 20 mA
02 = 4 ... 20 mA
Voltage
03 = DC 0 ... 10 V
04 = DC 0 ... 5 V
05 = DC 0 ... 2,500 mV
06 = DC 0 ... 1,250 mV
07 = DC 0 ... 600 mV
08 = DC 0 ... 300 mV
09 = DC 0 ... 150 mV
10 = DC 0 ... 75 mV
11 = DC 0 ... 35 mV
12 = DC 0 ... 18 mV
Temperature measurement
13 = Pt100 (4-/2-wire)
14 = Pt100 (3-wire)
15 = Pt200 (4-/2-wire)
16 = Pt200 (3-wire)
17 = Pt500 (4-/2-wire)
18 = Pt500 (3-wire)
19 = Pt1000 (4-/2-wire)
20 = Pt1000 (3-wire)
21 = L
22 = J
23 = K
24 = B
25 = S
26 = N
27 = E
28 = T
29 = R