7. Description of program numbers
7.1.2 Start and end value
With this value pair, the measuring signal is assigned the desired indication value.
PN
Function
1
End value (end of measuring range)
2
Start value (start of measuring range)
Procedure for standard signals
▶
Set the corresponding display values.
Procedure for non-standard input signals
1. Apply the end value of the input signal to the measuring input.
2. Select PN1.
3. Set the display value.
4. Press [☼].
⇒
Input signal is associated with display value.
5. Apply the start value of the input signal to the measuring input.
6. Select PN2.
7. Set the display value.
8. Press [☼].
⇒
Input signal is associated with display value.
⇒
Display values are assigned.
WIKA operating instructions digital indicator, model DI35-M
Parameter
-9999 ... 99999
-9999 ... 99999
EN