Safety devices

Pressure switch: monitors
depression in the smoke
duct. It is designed to shut
down the pellet feed screw
in the event of an obstruct-
ed flue or significant back-
pressure in the presence
of wind. At the time of the
pressure switch will show
"A L A R-D EP -F AIL".
RESTART
WATER
Safety thermostat with
manual reset for the wa-
ter temperature: if the
temperature of the water
tank exceeds the preset
safety level of 100 °C im-
mediately stops the op-
eration of the thermostove
and the display will show
"A L A R-S I C- FA IL". To restart
you need to reset manually.
Tampering with the safety devices is prohibited. It is only after eliminating the cause which gave
rise to the intervention of the safety system, that it is possible to relight the stove and thus reset
the automatic operation of the sensor. To understand which anomaly has occurred, consult this
manual at paragraph relating to alarms which explains what to do based on the alarm message the
stove display.
44
Reduction motor:
if the motor stops, the ther-
mostove continues to func-
tion until the flame goes out
for lack of fuel, and until It
has cooled down to the
minimum level.
Water temperature probe:
if the water temperature
approaches the blocking
temperature (100 °C), the
probe requires to interrupt
the supply of pellets.
Flue
gas
temperature
sensor: thermocouple that
measures the temperature
of the fumes while keeping
the operation or shuts the
thermostove when the flue
gas temperature drops be-
low the preset value.
Automatic vent valve: this
valve eliminates the air in-
side the thermostove and
of the heating system.
Electrical safety: the stove
is protected against violent
surges of current (ex. light-
nings) by the main fuse 4
A which is located on the
control panel at the rear of
the thermostove. Other fus-
es to protect the electronic
boards are to be found on
the boards themselves.
Safety valve: this valve acts
to prevent over pressuriza-
tion of the hydraulic system.
If the pressure of the ther-
mostove or plant exceeds
2.5 bar it drains the water
from the circuit.