Failure on electrical devices
Failed light-up
If the flame does not light up during the switching on or if
the smokes temperature does not reach a suitable value in
the foreseen time gap, the thermostove switches off and
you will read the words "Al ar No Ac c" on the display.
Press the key "On/Off" to reset the alarm. Wait until the
cooling phase is completed, clean the brazier and start a
new light-up.
Switching off while working
The thermostove suddenly switches off while working (for
example because it has run out of pellets in the tank or
because the motor reducer for pellets loading got broken).
The thermostove continues working until the pellets left
in the brazier ends. You will then read the words "A la r
No F i re " on the display and the stove switches off. Press
the key "On/Off" to reset the alarm. Wait until the cooling
phase is completed. Clean the brazier and start a new
light-up.
These alarms remind you that the brazier must be
cleaned and installed correctly before switching on
the thermostove.
There is no power supply
In the event of a power drop longer than one minute, the
thermostove can exhaust some smoke in the room: this
causes no risks.
As soon as you have the power supply again, the
thermostove will have the words "C oo l
the display. After completing the cooling phase, the
thermostove will start up again automatically according to
the previous settings.
Do not attempt to start the thermostove
before the required time or it may get
blocked. If this occurs, switch off the
switch on the back of the pellet boiler stove for 1
minute, set it on again and wait 10 minutes before
starting the thermostove again.
The power socket where the thermostove
is connected should be fitted with "earth
connection complying with regulations in
force." The Manufacturer shall not be held respon-
sible for damage to things or people resulting from
negligent installation.
46
Manual restart thermostat
System pressure safety
The system pressure is checked electronically and needs
to be between 0,5 and 2,3 bar. If this is not the case, the
pellet boiler stove signalises an alarm and shows the
words "Al ar Pr es s " on the display.
Press" on the display. Check the system pressure keeping
the key
bar value on the display.
The safety valve keeps anyway the value under 2,5 bar
letting the exceeding water flow out automatically.
Intervention in case of danger
In case of fire, disconnect the power supply, use a fire
extinguisher in accordance with, and if necessary, call the
fire department and then contact an authorised qualified
technical assistance
Fi r e " on
RESTART
WATER
pressed for some seconds. You will read the