REMARKS:
In case of repeated ignition lock-outs, while pellets
are fed regularly, there may be a problem caused by a
failing electric glow plug. In this case, while you wait for a
technician, the pellet boiler stove can be manually started
by using solid fuel cubes (firelighters).
Manual starting procedure:
• open the door;
• take a solid fuel cube and place it inside the brazier
together with some pellets;
• light a match and set fire to the solid fuel inside the
brazier;
• wait a couple of minutes, close the door;
• follow the regular ignition procedure.
Do not use any flammable liquid to start
the stove. During the reload phase, do not
bring the bag of pellets in contact with
the hot thermostove.
Working power and water temperature settings
The heating power is set by the
and
. A heating
keys
power at Po 9 is suggested
during the first working hours of
the stove.
To set the water temperature press the key
You will see the words "SE T h2 o" blinking on the upper
display. You will read the water temperature on the lower
display.
Room temperature setting
To set the room temperature,
press the key
: twice: you
will see the words "SET AI R ",
blinking on the lower display.
You will read the set temperature
on the upper display.
Use the keys
e
to change the value.
Room temperature range: 7°C – 40 °C
Procedure to turn off the
thermostove
Turn off the pellet boiler stove by
pressing button
, for a couple
of seconds until "OFF" is shown
on the upper display
Pellet feeding will stop immediately but the thermostove
will continue working until the accumulated heat is
fully consumed, turning itself off automatically after a
maximum of 30 minutes.
38
REMARKS:
The thermostove is fitted with
an automatic device that allows
cleaning the brazier after a
given period of time: when this
time is detected, the stove fire
automatically
"PU L F IRE "; is shown on the display. After some minutes,
the thermostove will start working regularly.
operation of the fumes extraction fan is normal
and may indicate that the stove is still hot. In the
event of low temperatures, it might happen that
the stove starts the smokes fan and circulator for
some minutes in order to prevent ice formation
on the pipes of the system. in the event there is a
power drop, the main board will exhaust the smokes
residuals as soon as the power supply is back on.
In order to do that, the main board will increase
the speed and show the words "C O O L FIR E " on the
display. As soon as the cooling phase has been
completed, the stove will automatically start up
working as it was set before the power drop.
. only once.
reduces
and
Do not unplug the power plug to turn off
the thermostove; wait until the automatic
shutdown cycle finishes: the continuous