Alarm signals

In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Upper
Lower
Display
Display
NO
ALAR
ACC
NO
ALAR
FIRE
SOND
ALAR
FUMI
HOT
ALAR
H20
SOND
ALAR
H20
HOT
ALAR
TEMP
COOL
FIRE
FAN
ALAR
FAIL
DEP
ALAR
FAIL
SIC
ALAR
FAIL
ALAR
PRESS
SERV
Regular checks should be carried out by the user, who should only contact the Authorized Assistance Center
if no solution is found.
Kind of failure
The thermostove cannot start up
This is the first light-up
The pellet boiler stove switched off while working
The smokes sensor is broken or not connected
to the pcb
The water temperature exceeds 90°C.
The circulating pump is blocked or there is no water
in the hydraulic system
The water sensor is not connected
There is a short circuit on the water sensor
The smokes temperature exceeds 280°C
There is no power supply
Smokes extractor blocked or broken
Obstructed flue
Pellets tank overheating
The system pressure does not reach 0,5 bar or
exceeds 2,3 bar
The stove has worked for 1300 hours.
Supplementary maintenance required
Solution
Fill in the tank with pellets
Start up again
Fill in the tank with pellets
Contact an Authorized Assistance Center
Check the power supply on the pump.
Check limestone does not block the pump
impeller
Check the water sensor is connected
Contact an Authorized Assistance Center
Smokes sensor failure
Contact an Authorized Assistance Center
As soon as the power supply is back, the stove
starts a cooling cycle. After completing the
cycle it starts working automatically
Contact an Authorized Assistance Center
Clean the flue or check there are no obstructed
grids near the smokes exhaust
Re-set the safety thermostat for pellets on the
back of the stove. If the problem occurs again,
contact an Authorized Assistance Center
Reduce the system pressure
Charge the system
Contact an Authorized Assistance Center
45