Thermostove start up
Remove any components wich might
burn from the firebox and from the glass
(various instructions and adhesive labels)
Charge pellet
Fuel is loaded from the upper part of the thermostove
by opening a door. Pour the pellets in the hopper. When
empty, it will hold slightly more than a 15 kg sack.
This is easier if performed in two steps:
• Pour half of the contents of the bag into the hopper and
wait for the fuel to settle on the bottom.
• Then pour in the rest.
Never remove the protection grille in the
hopper. When filling, do not let the sack of
pellets touch any hot surfaces.
The brazier should be cleaned before each
starting.
Control Panel (Fig. 2)
Button
is used to switch on and / or off the thermostove
and to exit programming.
Buttons
and
are used to adjust temperature, for
displays and for the programming functions.
Buttons
and
are used to adjust heating power.
Button
is used to adjust temperature and programming
functions.
The upper and lower displays are used to view different
messages.
Led
Symbol
The LED is on when the parameter
UT01 on the menu is not on OFF and
1
the weekly or daily programming are
set.
The LED starts up every time the stove
2
is loading pellets
The LED blinks when the board
signalises a change in temperature
3
or power set by the infrared remote
control.
The LED is on when the room
4
temperature reaches the value set on
the menu SET Water.
The LED blinks to indicate that you are
entering the menu user/technician or
"SET"
5
that you are modifying the temperature
set.
The LED switches on when the water
6
circulator is working.
Description
1
6
It is advisable to use dry wood pellets, up
to 6 mm in diameter.
Preliminary checks
Before switching on the pellet stove, make sure that the
pellet hopper is full, the combustion chamber is clean, the
glass door is closed, the power supply plug is connected
and the switch on the back is set to "1."
Starting the thermostove
Press button
for a couple of seconds until the ther-
mostove starts.
"F AN" will be displayed on the
upper display and "ACC" on the
lower one. During this phase the
unit will carry out a diagnosis
(around 20 seconds) on the fume
extraction system.
"L O AD WOO D ", is the next phase,
which indicates pellets should
be fed. The glow plug will heat
up to light the fire.
When the fume temperature is
50º C (approx. 10 minutes), the
thermostove will confirm the
ignition: "F IRE" will be shown on
the upper display and "O N " on
the lower one.
After this phase, which lasts
around 5 minutes, the heating
power (es. "p 06") and the room
temperature (es. "25C"), will be
simultaneously shown on the
upper display, and the system
delivery water temperature will
be shown on the lower display.
If the flame does not start up correctly within 10 minutes,
the thermostove jams: you will read the words "A L AR" on
the upper display and the words "N O AC C ": blinking on the
lower display.
Wait 10 minutes until the cooling phase is completed,
open the door, empty the brazier and start a new light-up.
2
3
4
5
Fig. 2