CONNECTING THE 433 MHZ MODULE ANTENNA
The receiver is supplied with its own antenna which consists of a piece of rigid wire 170 mm in length. In
alternative it is possible to connect an ANS400 tuned antenna using a coaxial cable RG58 (impedance 50Ω)
with a maximum length of 15 m.
ELECTRICAL INPUT SENSOR COMPENSATION
Measuring the electrical input of the motors is carried out in order to be able to compensate for any small variations
caused by environmental conditions; Should this occur a flashing hyphen will appear on the display (the quicker it
flashes the greater the compensation required). The hyphen will appear on the left of the display for sensor "1" and on
the right of the display for sensor "2" (see "Indications on the display" page 17-18).
Each time the movement is blocked (even the inversion command) the compensation factor will be reset and
recalculated so as to be continuously updated.

FUNCTION MODES

1) Automatic
Selected by enabling automatic reclosing (programming step 6, number "6" not flashing).
When the door is completely closed the opening command will start a complete cycle which will end with
automatic reclosing and the night light switching off.
Automatic reclosing starts after the programmed pause period has elapsed when the opening cycle has been
completed or straight away after the intervention of a photoelectric cell (the intervention of a photoelectric
cell causes the pause time to be reset).
During the pause time the symbol
period will stop automatic reclosing and consequently stop the display from flashing. The intervention of the
mechanical travel limits or the electrical sensor will block the door/gate. The indicator light remains lit until
the closing manoeuvre has terminated.
Note: the night light switches on automatically each time a movement command is given either by control
button or by radio. The intervention of a photoelectric cell during reclosing has no effect on the timing
of the night light.
2) Semiautomatic
Selected by disabling automatic reclosing (programming step "6", number "6" flashing).
Work cycle control using separate opening and closing commands. When the door has reached the completely
open position the system will wait until it receives a closing command either via an external control button or via radio
control, before completing the cycle. The activation of one of the travel limit switches causes the door to stop and the
termination of the opening/closing cycle. Starting from the opening manoeuvre the night light will switch off after the set
period has elapsed. The indicator light remains lit until the closing manoeuvre has terminated.

LIMITED OPENING

This only effects gate 1; If a double gate leaf system has been selected, gate leaf 1 will open completely. If a single
gate leaf system has been selected, gate leaf 1 will open for about a third of its opening angle (pedestrian function).
The command can only be carried out with the gate leaves completely closed; if you press "TAL" again during
opening leaf 1 will block and the next command will send it in the closing direction. At this point the command can
only be used after the gates leaves are once again completely closed.
NIGHT LIGHT/SECOND RADIO CHANNEL CH2
Binding posts "7","8" are wired to the C-N0 contacts of a relay. This function can be activated as a normal "night
light" (normally closed contact) for the programmed period of time or may be used as second radio control channel
selected on the integrated decoder (jumper "J1").
Binding posts "7","8" have a direct contact and as it does not output any voltage it only functions as a simple switch.
This means that an eventual night light must receive its power externally.
Attention! There is no 230Vac connection on the main circuit board (only the low voltage 24V circuit
is present. The standards and regulations in force regarding the isolation of low (24Vac) and high voltage
circuits (230Vac) means that you must not directly connect a device which applies a voltage of 230Vac
to the binding posts "7" and "8".