ELECTRONIC PROGRAMMER

Electronic programmer for two direct current motors with an incorporated radio receiver card, which allows the
memorisation of or 300 user codes depending on the model (see "remote control" page 22). The 'rolling code'
type decoder uses 433,92 MHz. series transmitters. The travel speed is electronically controlled, starting slowly and
increasing in speed; the speed is reduced as it nears the travel limit so as to enable a controlled smooth stop (if
deceleration hasn't been excluded during programming).
Programming is carried out using two buttons and allows you to configure the system, set the length of the
deceleration stage and set the work and pause times.
The intervention of the anticrush/antidrag sensor during the closing and opening stages causes travel direction
inversion (if automatic reclosing has been enabled).
All rights reserved. Unauthorised copying or use of the information contained in this document is punisha
If activated towards the end of the movement (almost closed) it will act as a travel limit.
Electronic card description
Legend
B1
Signal buzzer "via radio" mode
DS1 Seven segment display
F1
1A rapid action fuse - 24V circuit overload protection
F2
3,15A delayed fuse - electric locking device overload protection (only in battery powered mode)
F3
10A rapid action fuse - motor overload protection
F4
10A rapid action fuse - motor overload protection
J1
Channel selection
J2
Enable transmitter memorisation via radio
(without opening the container)
L1
LED power on
L2
LED transmitter code management
L3
LED manual operation
L4
LED closing travel limit
leaf 1 (FCC1)
L5
LED opening travel limit
leaf 1 (FCA1)
L6
LED closing travel limit
leaf 2 (FCC2)
L7
LED opening travel limit
leaf 2 (FCA2)
L8
LED TA opening button activated
L9
LED TC closing button activated
L10 LED TB blocking button activate
L11 LED FTC_I inveverting
photoelectric cells activated
L12 LED FTC_S stop photoelectric
cells activated
M1
Memory module (300 codes)
P1
Programming button
P2
Selection button
P3
Transmitter code
memorization button
P4
Transmitter code
cancellation button
R1
433,92 MHz RF module
V0-V1 Transformer secondary 1
Faston connection (0-24Vac)
grey-grey
VB
Battery voltage connection
12Vdc (only for the electric
locking device in battery
powered mode)
V2-V3 Transformer secondary 2
Faston connection (0-15Vac)
brown-brown
V4-V5 Transformer secondary 3
Faston connection (0-20Vac)
red-red
M1
A)
S449
J1
CHD
J2
J2
CHC
CHB
Selezione canali
Channel selection
CHA
Sélection canal
29 30
Kanalwahl
Selección
CH 1
Comando dinamico
Dynamic command
Commande dynamique
Dynamische Steuerung
Mando dinámico
A
C H
B
C H
C
C H
D
C H
CH 2
Comando ausililiario
Auxilliary command
Commande auxiliare
Hilfssteuerung
F3
Mando auxiliar
A
C H
B
C H
C
C H
D
C H
L1
V5 V4 V3 V2
15
SPR
B1
F10A
F2
1
CMN
FTC_S
FTC_I
TB
CMN
CMN
TD
TC
TA
TAL
FCA2
FCC2
FCA1
FCC1
CMN
OUT 24V
LP 24V
LS 24V
LC- OUT CH2
ELS 12V
CMN
V1
V0
VB
T3.15A