Release Contact
With the release contact closed, the lock is released / cleared. With the contact open,
the lock is disabled / blocked and cannot be opened.
Contact closed:
Contact open:
Note:
With the BAS emitting live signals (12V) as release signals only, use jumper 1.
Alarm Contact:
If a user enters an alarm code when opening (=opening code, last digit+1,) at operating
unit CombiControl, a duress - / silent alarm will be triggered at the output relay. The
contact closes for about 1 sec.
Standby:
Terminals 10 and 11 closed
Silent alarm:
Triggered, lasting ca. 1 sec
Terminals 10 and 12 closed
Status Contact
The current state of the lock (open /closed) is indicated via relay 'status'.
Lock open
Terminals 9 and 7 closed
Lock closed
Terminals 9 and 8 closed
INSYS locks
CombiLock 200 simplex / pro / pro RFID
Lock is released / cleared
(terminals 19 and 20 electrically connected)
Lock blocked / disabled (opening is impossible)
(terminals 19 and 20 open)
75
Resistance monitoring
R1
R2
Resistance monitoring
Resistance monitoring
R3
R4
Resistance monitoring
Manual V.1.09A
Terminal 11
No Alarm
Terminal 10
Alarm
Terminal 12
Terminal 8
Closed
Terminal 7
Open
Terminal 9