CombiLock 200 simplex / pro / pro RFID
6 Trouble Shooting and Maintenance
6.1
Optic and Acoustic Signals
Signal
2 x
Q
green 1 x
Q
red and 12 x
Q
green and 2 x
Q
red and 12 x
Q
green flashes every
5 sec.
Q
15 x
then
green
Q
red flashes every 5
sec.
Q
green and 2 x
Q
red and green flash
intermittently 10 x and
10 x
Q
green and 1 x
then
Q
red and 1 x
Handbuch V.1.09A
Reason
Electronic lock off
Correct code entry.
Incorrect code entry.
Modification /
Change OK.
Invalid attempt at
change.
Timed delay is
running.
Release time is
running (Time delay
has ended).
Lockout / blocked
time is running.
Lockout / blocked
time has ended.
Battery charge low –
Warning.
Keypad has been
,
tampered with or
changed, battery
compartment has
been opened.
62
Comment
In order to switch on, press
2 sec.
A lockout / blocked time of 10 sec.
follows after the code has been entered
incorrectly 4 times in succession. Each
additional incorrect entry prolongs the
lockout by 10 sec. Enter PIN and valid
Code two times after the lockout
ends.
The CODE change or the activation /
deactivation of a supplementary function
has been carried out properly.
Code change or switching on or off an
additional function carried out
incorrectly. Repeat process.
The electronic lock does not respond to
any key entry while the timed delay is
running.
See section 3.8, Opening with Time
Delay, Alarm Delay and Release Time.
Lockout / blocked time cannot be
discontinued / interrupted!
Signal indicating that the electronic
lock can be opened with the correct
Code.
2 x 1.5 volt MICRO batteries
Type AAA Alkaline (not rechargeable)
should be replaced shortly.
Codes remain the same after
battery change. Enter PIN and code
twice after replacing the battery.
In order to open the electronic lock,
enter PIN und CODE once again.
for
INSYS locks