7.2.5
Mounting the Attachment Ring
Mount the attachment ring for keypad CombiControl according to the illustration.
In order to do this, if required,
drill 4 M4 threaded holes,
and, if not carried out already
(see section 7.2.1 above):
drill 1 bore for spindle variant B,
Ø min. 10.5 – max. 13 mm
(11 mm in ill. to the right)
or
drill 1 bore for spindle variant A,
Ø min. 8.2 mm, max. 12 mm
into the safe door.
Keypad centre axis is congruent
with lock centre axis.
7.2.6
Mounting the Keypad
Mount the keypad onto the attachment ring at an angle of about 20
wards rotate the keypad clockwise to the right until it fits. See illustrations above.
With the keypad aligned in vertical direction, it is not released, but blocked.
In order to release the keypad (to change keypads, for example), open it first (see
section ‚Opening the Keypad' on page 63) and release it (see section ‚Releasing the
Keypad' on page 70).
Tastatur unter einem Winkel
INSYS locks
von ca. 20° auf den Befestigungsring
aufstecken und anschließend durch
CombiLock 200 simplex / pro / pro RFID
Attachment ring for keypad
After that, with four M4x8 machine screws fasten
the attachment ring with a max. torque of 1 Nm
ensuring that there is no damage in the area
where the ring is secured.
69