Herunterladen Inhalt Inhalt Diese Seite drucken

Initial Start-Up; Shutting Down - Bosch EFEP 60H Originalbetriebsanleitung

Düsenprüfgeräte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
14 | EFEP 60H / EFEP 67D | Product description
2.4.2
EFEP 67D
Testing nozzles of size
Pressure gauge range
7
6
5
4
3
Fig. 2:
EFEP 67D
1 Oil tank with filter
2 Shutoff valve with valve spindle
3 Fastening screws for manual operating lever
4 Manual operating lever
5 Warning notice: "Do not reach into test jet".
6 Pressure outlet (test pressure line connection)
7 Pressure gauge
*)
for overview on last but one page.
*)
2.4.3
Switching off the pressure gauge
Turn shutoff valve handle (Fig. 1 and 2, 4) as far as
possible to the right.
|
1 689 979 086
2018-06-08
T, U, V, W
0...60 MPa (0...600 bar)
40 0
50 0
30 0
30 0
20 0
40 0
20 0
50 0
10 0
10 0
60 0
1
2
2.5
Initial startup
1. Fit manual operating lever.
2. Fit pressure gauge (0 684 200 700 only).
3. Fill oil tank at least halfway with test oil complying
with ISO 4113.
4. Unscrew oil tank slightly.
5. Operate manual lever until the oil exits at the
pressure outlet with no bubbles.
6. Tighten oil tank again by hand.
2.6

Shutting down

!
Oils are fluids that are hazardous to water and must
be disposed of in line with waste disposal legislation.
i
ISO test oil is a category 1 waste oil type, which
includes re-usable, low viscosity mineral engine
and gear oils. Category 1 waste oil may not contain
any external substances such as waste oil from a
different category or gasoline.
The waste oils described above must be disposed of
through commercial oil disposal companies at a cost to
the user. The associated waste disposal code number
"54 112" must be specified to ensure correct disposal.