Herunterladen Inhalt Inhalt Diese Seite drucken

Pump Fixing - Agilent Technologies Turbo-V 1K-G Bedienungshandbuch

Turbomolekularpumpen
Vorschau ausblenden Andere Handbücher für Turbo-V 1K-G:
Inhaltsverzeichnis

Werbung

16
Instructions for Use

Pump fixing

Pump fixing

If a rotor failure occurs, the connection of the pump to the system could be
WARNING!
subjected to a significant torque. If the connection is not sufficient to
withstand that torque, the pump could detach from the system or the motor
housing could detach from the pump envelope. In this case metal fragments
could be projected from the pump or system, which could cause serious
injury or death and/or damage to surrounding equipment.
Fix the Turbo-V 1K-G Retrofit in a stable position mounting the inlet
flange of the turbopump to the system counter-flange, with a
connection capable of withstanding a torque of 8900 Nm around its
axis.
The following table shows, for each ISO-F flange, the necessary
number of screws and the relevant fixing torque.
Tab. 1
FLANGE
ISO 160 F
ISO 200 F
The class of the steel screws for "F" flange must be > 8.8
The Turbo-V 1K-G Retrofit ca be installed in any position.
WARNING!
The Turbo-V 1K-G Retrofit cannot be fixed by means of its base.
232/294
N.
8
12
Turbo-V 1K-G Retrofit User Manual / 87-900-996-01 (B)