Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic EYFLA7A Bedienungsanleitung Seite 22

Akku-schlagschrauber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
2. Press button D twice.
EN
• The current set value is displayed, and
the main unit panel starts flashing.
Display: U flashing.
Battery capacity indicator: The upper and
lower bars flash.
[Fig.34]
3. Press
and
the time.
Operation
4. Press the OK button to accept the new
setting.
• The control panel stops flashing and lights
up to display the torque clutch settings.
NOTE:
Check the new value after you change the
settings.
as required to change
Display
Seconds
U9
3
U8
2.5
U7
2
U6
1.5
U5
1.2
U4
1
U3
0.7
U2
0.5
U1
0.3
U0
0.1
U
OFF
Initializing all settings
Factory settings
• Torque clutch setting: "F" (torque control
function off)
• Interval setting: U or 0 (OFF)
• Snug point detection level → L1
• Cross thread reduction function → R0
• Rundown error detecting function → 0
• Tightening time reminder → 0
• Radio signal range limitation function
→ C0
• Buzzer setting → b0
• LED light setting → d1
• Speed control setting → P0
• Undetect time setting → J0
• Impact speed setting corresponding to
the length of the socket used → h0
[EYFLA7AR, EYFLA8AR, EYFLA8CR,
EYFLA8PR, EYFLA9CR, EYFLA9PR,
EYFMA2CR, EYFMA2PR]
• One-way and two-way communication
function → q 0
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
• The error display will be turned off.
1. Set the tool to the setting configuration
mode.
(See page 18.)
2. Press the C button.
The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
[Fig.35]
3. Press the OK button to accept the
selected setting.
The control panel will stop flashing and
light up.
Checking Tool Settings
• This section describes how to have the
The current set value will display for
another 2 seconds after the tool stops
operation.
• The set status cannot be checked when
the tool panel is off. You can press the
trigger switch once to turn on the panel.
- 22 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading