  • DEUTSCH, seite 31
torque. Set the number of torque stag-
es again after making this change.
IMPORTANT INFORMATION:
• Pressing the A button toggles the dis-
play between the snug point detec-
tion level setting value and the num-
ber of torque stages setting value.
• The tool ships with the snug point
detection level set to "L1."
• When the number of torque stages
has been set as shown below, the
snug point detection level cannot be
switched from "L1" to "L2 ~ L7."
Number of torque stages
Model
EYFLA7
EYFLA8
EYFLA9
EYFMA2
Cross thread reduction function
The tool runs in reverse approximate-
ly 360° before running forward to assist
in the alignment of the threads to help
reduce cross threads.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the D button once.
The cross thread reduction function setting
value will be displayed.
3. Press the
and
the setting to ON or OFF.
Display
R0
R1
4. Press the OK button to accept the
new setting.
Rundown error detecting function
The rundown error detecting function
causes a red indicator to flash if work
ends more quickly than a set time, for
example due to retightening of a previ-
ously tightened fastener or binding of the
screw's thread.
1. Set the tool to setting configuration
mode. (See page 18.)
setting
1 to 40
1 to 40
1 to 40
1 to 40
buttons to change
Function
OFF
ON
- 19 -
2. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
[Fig.27]
3. Press the
and
time as desired.
Buttons
Display
4. Press the OK button to accept the
selected setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 360°.
Radio signal range limitation
function on/off setting
1. Set the tool to configuration mode.
(See page 18.)
2. Press the C button.
The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and lower
bars of the battery flash on and off.
[Fig.28]
3. Press the C button twice.
• Radio signal range limitation function
ON/OFF setting value will be displayed.
[Fig.29]
4. Press the
and
radio signal range limitation function
ON/OFF.
Radio signal
Display
range limitation
function mode
C0
OFF
C1
ON
5. Press the OK button to accept the
new setting.
buttons to change the
Seconds
30
3
1
0.1
0
OFF
buttons to set
Status
Tool is operational in the ab-
sence of communications with
the Assembly Qualifier.
Tool is not operational
in the absence of com-
munications with the As-
sembly Qualifier.
EN