Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic EYFLA7A Bedienungsanleitung Seite 20

Akku-schlagschrauber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
NOTE:
EN
• For more information about how to register
the tool and Assembly Qualifier, see the
Assembly Qualifier instruction manual.
Factory settings
• Radio signal range limitation function
setting: C0 (OFF)
One-way and two-way Communication
function setting (EYFLA7AR,
EYFLA8AR, EYFLA8CR, EYFLA8PR,
EYFLA9CR, EYFLA9PR, EYFMA2CR,
EYFMA2PR)
1. Set the tool to configuration mode.
(See page 18.)
2. Press the C button four times.
The control panel will begin flashing.
Display: The letter " q 1" flashes on and off.
[Fig.30]
3. Press the OK button to accept the new
setting.
Display
q 0
One-way Communication
q 1
Two-way Communication
NOTE:
• Panasonic Assembly Qualifier Model
No.EYFR02 : One-way communication only
Factory settings
• One-way and two-way communication
function setting: q 0 (One-way communi-
cation)
Two-way Communication displays
• When the tool is in "Two-way Commu-
nication Stand by" mode, Tightening
confirmation lamp blinks in Orange to
indicate.
[Fig.17]
• The control panel display shows the
tool's mode.
[Fig.31]
Display
- -
Operation Disabled Mode
CP
Function
Status
Tightening complete
Tightening time reminder
The tool is locked when it reaches the
set tightening time, and the main unit
stops operation. This feature is conve-
nient for regular inspection of the tool
performance.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the C button twice.
The setting value will be displayed.
3. Press
and
change the time.
Operation
4. Press the OK button to accept the new
setting.
NOTE:
• When the remaining time prior to the
tightening time is less than 1 hour, the
display will alternate between the "set
value" and "-1".
If the current tightening time remains
unchanged and the inspection duration
is extended, the new set value must be
greater than the current one.
When it reaches the set time, the
display alternates between the set
value and 0.
Buzzer setting
You can select from three buzzer modes.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the A button twice.
The current setting value will be displayed.
3. Press the
desired value.
Display
b0
b1
Buzzer accompanying green indicator
b2
Buzzer accompanying red indicator
4. Press the OK button to accept the new
setting.
- 20 -
buttons as required to
Display Tightening time
99
99 hours
1
1 hour
0
OFF
and
buttons to set the
Function
No buzzer

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis