Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Maintenance Work; General Maintenance Procedure For The Outdoor Unit - Hitachi YUTAKI Serie Installations- Und Betriebshandbuch

Vorschau ausblenden Andere Handbücher für YUTAKI Serie:
Inhaltsverzeichnis

Werbung

MAINTENANCE

Code
Category
number
b1
Incorrect setting address or refrigerant cycle
Number setting
Incorrect setting of indoor unit number for
b5
H-LINK type

Alarms for LCD
Retry
Alarm
Yutaki
Stop
Code
S/SC
Code
202
(o)
203
(o)
204
(o)
205
(o)
10 MAINTENANCE

10.1 MAINTENANCE WORK

!
C A U T I O N
All inspections and checks have to be carried out by a licensed technician and never by the user itself.
Before any inspection and check the unit main power supply has to be switched OFF.
Wait a minimum off 10 minutes from all power supply have been turned OFF.
Take care with the crankcase heater. It could operate even when compressor is OFF.
Take care with the electrical box components. Some of them could remain hot after switching OFF the unit.
?
N O T E
All these maintenance operations must be done with appropriate materials and following this manual.

10.1.1 General maintenance procedure for the outdoor unit

1 Fan and fan motor
Lubrication: All the fan motors are pre-lubricated and sealed at factory. Therefore no lubrication maintenance is required.
Sound and vibration: Check for abnormal sounds and vibrations.
Rotation: Check the clockwise rotation and the rotating speed.
Insulation: Check the electrical insulation resistance.
2 Heat exchanger
Clog: Inspect the heat exchanger at regular intervals and remove any accumulated dirt and any accumulated dust from the heat
exchanger. Other obstacles must be removed such as the growing grass and the pieces of paper which might restrict the airflow.
3 Refrigerant piping connection
Leakage: Check for the refrigerant leakage at the piping connection between the outdoor and the indoor unit.
Pressure: On split system, check the R-410A refrigerant pressure using the check joints of the outdoor unit.
4 Cabinet
Stain: Check for any stain and remove it cleaning if it is the case.
Fixing screw: Check for any loosened screw or any lost screw. Fix the loosened screws and the lost screws.
Insulation material: Check for any peeled thermal insulator on the cabinet. Repair the thermal insulator.
5 Electrical equipment
Activation: Check for an abnormal activation of the magnetic contactor, the auxiliary relay, the PCB and others.
Line condition: Pay attention to the working voltage, the working amperage and the working phase balance. Check for any faulty
174
PMML0335A rev.1 - 04/2016
Type of abnormality
Yutaki
Yutaki
Origin
S80
M
(o)
(o)
LCD
(o)
(o)
LCD
(o)
(o)
LCD
(o)
(o)
LCD
Over 64 indoor units setting by number or indoor unit address.
The number of indoor units connected to the H-LINK II of one
system is 17 or higher.
Detail of Abnormality
Wrong settings of PC-ARFHE
Slave PC-ARFHE stops answering
to Master PC-ARFHE
Indoor unit stops answering to
Master PC-ARFH
Central Alarm, no Central message
Main cause
Main Factors
Loose, disconnected, broken or
short-circuited connector
Loose, disconnected, broken or
short-circuited connector
Loose, disconnected, broken or
short-circuited connector

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Yutaki mYutaki s combiYutaki s80

Inhaltsverzeichnis