UNIT CONTROLLER
Inputs range visualizations and constraints table:
Value
1
0
Disabled
O
1
Demand On/Off
O
2
Smart Act / SG 1
X
Swimming Pool
3
X
input
4
Solar
X
5
Operation Mode
O
6
DHW Boost
X
7
Power Meter 1
X
8
Demand On/Off C1
O
9
Demand On/Off C2
O
10
Forced Heating
O
11
Forced Cooling
O
12
Power Meter 2
O
ECO Mode C1&C2
13
O
(*1)
14
ECO Mode C1 (*1)
O
15
ECO Mode C2 (*1)
O
16
Forced OFF
O
17
SG 2
O
?
N O T E
(*1) When ECO Mode input function is used and a timer is configured with Eco periods take into account that configuration could be overwritten.
These options cannot be repeated.
159
PMML0335A rev.1 - 04/2016
Available at
2
3
4
5
6
7
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
O
X
X
X
O
X
X
X
X
X
X
O
X
X
X
O
O
O
O
O
O
X
X
X
X
O
X
X
X
X
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Always
Available if some of the Water Calculation modes (Water calculation mode
for circuit 1 heating (C1WC) or Water calculation mode for circuit 1 cooling
(CC1WC) or Water calculation mode for circuit 2 heating (C2WC) or Water
calculation mode for circuit 2 cooling (CC2WC)) are not set as "Disabled". It is
not shown if Demand On/Off C1 or Demand On/Off C2 are configured.
Available if 8-200 ("Status" of Smart function in Optional functions menu) is
"Enabled"
Available if Status (SWP) ("Status" of Swimming pool menu) is "Enabled"
Available if Solar combination (SOLStSet) ("Status" of Solar combination in
Complementary Heating menu) is "Enabled"
Available if cooling operation is enabled (DSW1-4: ON). Not available for
YUTAKI S80
Available if DHW Boost (AutoT) ("DHW Boost" in DHW of the Optional
functions menu) is set as "Open" or "Closed" and Status (DHWs) is set as
"Enabled"
Available if 8-102 ("Power meter 1" in Energy configuration of the Optional
functions menu) is not "Disabled" and Status (PMConf) ("Status" in Energy
configuration of the Optional functions menu) is "Enabled"
Available if Water Calculation modes for circuit 1 (Water calculation mode
for circuit 1 heating (C1WC) for heating or Water calculation mode for circuit
1 cooling (CC1WC) for cooling) are not set as "Disabled". It is not shown if
Demand On/Off is configured.
Available if Water Calculation modes for circuit 2 (Water calculation mode
for circuit 2 heating (C2WC) for heating or Water calculation mode for circuit
2 cooling (CC2WC) for cooling) are not set as "Disabled". It is not shown if
Demand On/Off is configured.
Available if cooling operation is enabled (DSW1-4: ON). Not available for
YUTAKI S80
Available if cooling operation is enabled (DSW1-4: ON). Not available for
YUTAKI S80
Available if 8-103 ("Power meter 3" in Energy configuration of the Optional
functions menu) is not "Disabled" and Status (PMConf) ("Status" in Energy
configuration of the Optional functions menu) is "Enabled"
Available if some of the Water Calculation modes (Water calculation mode
for circuit 1 heating (C1WC) or Water calculation mode for circuit 1 cooling
(CC1WC) or Water calculation mode for circuit 2 heating (C2WC) or Water
calculation mode for circuit 2 cooling (CC2WC)) are not set as "Disabled". It is
not shown if ECO Mode C1 or ECO Mode C2 are configured.
Available if Water Calculation modes for circuit 1 (Water calculation mode for
circuit 1 heating (C1WC) for heating or Water calculation mode for circuit 1
cooling (CC1WC) for cooling) are not set as "Disabled". It is not shown if ECO
Mode C1&C2 is configured.
Available if Water Calculation modes for circuit 2 (Water calculation mode for
circuit 2 heating (C2WC) for heating or Water calculation mode for circuit 2
cooling (CC2WC) for cooling) are not set as "Disabled". It is not shown if ECO
Mode C1&C2 is configured.
Always
Available if 8-200 ("Status" of Smart function in Optional functions menu) is
"Enabled" and 8-201 ("Smart Action" in System option of the Optional functions
menu) is set as "SM Grid Ready"
Constraints