GENERAL DATA
3.2 ERP PERFORMANCE DATA
3.2.1 General considerations
•
This appliance must be installed, maintained and dismantled by professionals. Do not pour contained refrigerant into the
atmosphere since this refrigerant fluid is a fluorinated greenhouse gas regulated under European Regulation (EU) No 517/2014.
•
Data with the mark (*) corresponds to the "Energy efficiency contribution (η
OTC control (Factory-supplied)
Temperature control class
Energy efficiency contribution
(*) Factory supplied in case of Yutaki S, SC and S80 DHW Tank
•
Data between brackets corresponds only to heating and cooling models ("Cooling kit" accessory needed).
3.2.2 General ERP data for space heaters
3.2.2.1 ERP data - YUTAKI S
AVERAGE climate
RAS-(2-3)WHVNP + RWM-(2.0-3.0)NE
Model
Water outlet temperature
Air to water heat pump
Heat pump combination heater
Product
description
Low temperature heat pump
Complementary heater
Design capacity (P
)
DESIGN
Nominal energy efficiency (η
)
S
Nominal energy class
Data for Packaged Fiche:
Energy efficiency with OTC control (η
Energy class with OTC control
Energy efficiency with thermostats/sensors (η
Energy class with thermostats
Supplementary capacity (P
)
SUP
Type of energy used
Declared capacity (Pdh) and coefficient of performance (COP
Outdoor temperature (Tj) = -7ºC
Outdoor temperature (Tj) = +2ºC
Outdoor temperature (Tj) = +7ºC
Outdoor temperature (Tj) = +12ºC
Outdoor temperature (Tj) = Bivalent
temperature (T
)
biv
Outdoor temperature (Tj) = Limit operation
temperature (TOL)
Bivalent temperature (T
)
biv
Limit operation temperature (TOL)
Water limit operation temperature (WTOL)
Degradation coefficient (Cdh)
Annual energy consumption (Q
HE
19
PMML0335A rev.1 - 04/2016
II
Temperature control class
+2%
Contribution to the nominal energy efficiency
Outdoor unit
Indoor unit
-
-
-
-
kW
%
-
) (*)
%
S
-
) (*)
%
S
-
kW
-
) at partial load under the following outdoor temperatures:
d
Pdh
kW
COP
-
d
Pdh
kW
COP
-
d
Pdh
kW
COP
-
d
Pdh
kW
COP
-
d
Pdh
kW
COP
-
d
Pdh
kW
COP
-
d
ºC
ºC
ºC
-
)
kW·h 1719 (1675) 2341 (2298) 2569 (2525) 3110 (3066) 3286 (3242) 3714 (3671)
)" due to the use of temperature control.
S
Wired room thermostat (PC-ARFHE)
Wireless room thermostat (ATW-RTU-04)
Wired room sensor (ATW-ITS-01)
RAS-2WHVNP
RAS-2.5WHVNP
RWM-2.0NE
35ºC
55ºC
35ºC
4.0
4.0
6.0
189 (194)
137 (140)
177 (180)
A+++
A++
A+++
191 (196)
139 (142)
179 (182)
A+++
A++
A+++
193 (198)
141 (144)
181 (184)
A+++
A++
A+++
0.0
0.6
0.3
3.54
3.50
4.95
3.20
2.20
2.70
2.15
2.10
3.01
5.20
3.73
4.60
1.70
1.60
1.90
6.05
4.40
6.00
1.75
1.60
1.80
6.25
5.00
7.20
3.54
3.50
4.95
3.20
2.30
2.70
4.00
3.40
5.30
2.75
2.10
2.50
-7
-7
-10
-10
-10
55
55
0.9
0.9
0.9
7E543002(*)
7E543003
7E549932
RAS-3WHVNP
RWM-2.5NE
RWM-3.0NE
55ºC
35ºC
Yes
No
No
Yes
5.0
7.0
130 (132)
165 (167)
A++
A++
132 (134)
167 (169)
A++
A++
134 (136)
169 (171)
A++
A++
0.7
0.6
Electricity
4.42
5.90
1.85
2.50
2.69
3.59
3.45
4.40
1.84
2.31
4.20
5.35
2.06
2.10
6.90
6.15
4.42
5.90
1.85
2.50
4.30
6.40
1.80
2.30
-7
-7
-7
-15
-10
55
55
55
0.9
0.9
VI
+4%
55ºC
6.0
125 (127)
A++
127 (129)
A++
129 (131)
A++
0.8
5.10
1.84
3.10
3.20
2.00
4.45
2.30
5.96
5.10
1.84
5.20
1.65
-7
-15
55
0.9