(*1): "HP+Heat+Boil" is not available for YUTAKI S80 and M.
Electrical Heater
REF
Access
HEBP
Bivalent Point
HEksco
Supply Setting Offset
HEPB
Proportional Band
HEIRF
Reset Factor
HEISWT
Inter Stage Time
HEWTEH
Waiting Time
?
N O T E
(*1): If Heating source (HES)= "HP+Heat.+Boil.", the bivalent point for electric heater must be equal or higher than the bivalent point for boiler + 5 ºC of
offset (Bivalent point (HEBP) ≥ Bivalent point (BOBP) + 5 ºC)
Boiler Combination
REF
Access
BOBP
Bivalent Point
BOCM
Combination mode
BOksco
Supply Setting Offset
BOon
Minimum ON Time
BOoff
Minimum OFF Time
BOWt
Waitting Time
BODHW
DHW by Boiler
BODWt
Wait Time for DHW
?
N O T E
•
(*1): If Heating source (HES)= "HP+Heat.+Boil.", Bivalent point (BOBP) has a range withing -15 and 20ºC.
•
(*2): If Heating source (HES)= "HP+Heat.+Boil.", the bivalent point for electric heater must be equal or higher than the bivalent point for boiler + 5
ºC of offset (Bivalent point (HEBP) ≥ Bivalent point (BOBP) + 5 ºC).
•
(*3): If Status (DHWs)= "Enabled". This parameter is not displayed in case of YUTAKI S80 (Version for combination with DHW).