UNIT CONTROLLER
Question
Description
Question 5a
Which are the emitters of circuit 1?
Question 5b
Which are the emitters of circuit 2?
Do you have domestic hot water tank
Question 6
installed?
Do you have swimming pool
Question 7
installed?
Question 8
Do you have boiler installed?
Do you have electric backup heater
Question 9
installed?
Question 10 Select the bivalent point:
Question 11
How many thermostats are installed?
Question 12
How are they connected?
123
PMML0335A rev.1 - 04/2016
Answers
Water calculation mode for circuit 1 heating (C1WC) = "Gradient"
Underfloor
heating
Gradient curve for circuit 1 (C1OTC) = "0.4"
Water calculation mode for circuit 1 heating (C1WC) = "Fix"
Fan coils
Fixed T for circuit 1 (C1TF) = "45"
Water calculation mode for circuit 1 heating (C1WC) = "Gradient"
Radiators
Gradient curve for circuit 1 (C1OTC) = "1.2"
Water calculation mode for circuit 2 heating (C2WC) = "Gradient"
Underfloor
heating
Gradient curve for circuit 2 (C2OTC) = "0.4"
Water calculation mode for circuit 2 heating (C2WC) = "Fix"
Fan coils
Fixed T for circuit 2 (C2TF) = "45"
C2WC = "Gradient"
Radiators
Gradient curve for circuit 2 (C2OTC) = "1.2"
No
Status (DHWs) = "Disabled"
Yes
Status (DHWs) = "Enabled"
No
Status (SWP) = "Disabled"
Yes
Status (SWP) = "Enabled"
No
-
Yes
-
If question 8 has been answered as "Yes":
- Heating source (HES) = "HP+Boiler"
No
If question 8 has been answered as "No":
- Heating source (HES) = "HP Only"
If question 8 has been answered as "Yes":
- Heating source (HES) = "HP+EH+Bo."
Yes
If question 8 has been answered as "No":
- Heating source (HES) = "HP+Heater"
If questions 8 and 9 have been answered as "Yes":
a) If value is <"-15":
- Bivalent point (BOBP) = Value
- Bivalent point (HEBP) = Value + 5
b) If value is ≥"-15":
-20 to 20
- Bivalent point (HEBP) = Value
- Bivalent point (BOBP) = Value - 5
If question 8 has been answered as "Yes" and question 9 as "No":
- Bivalent point (BOBP) = Value
If question 8 has been answered as "No" and question 9 as "Yes":
- Bivalent point (HEBP) = Value
0
Thermostat type (RTType) = "None"
1
-
2
-
If question 11 has been answered with a value different than "0", "Check RT
Wired
address" is launched.
If question 11 has been answered as "1":
- Thermostat 1 (otC1) = "C1"
- Thermostat 2 (otC2) = "None"
Wireless
If question 11 has been answered as "2":
- Thermostat 1 (otC1) = "C1"
- Thermostat 2 (otC2) = "Room C2"