Herunterladen Inhalt Inhalt Diese Seite drucken

In-Place Sanitization; Maintenance - Ugolini Quick-Gel Gebrauchsanweisung

Eiscreme-dispenser
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
operating the dispenser; avoid leaving it unused for any
length of time after sanitising.
1 Before beginning the procedures described below, wash
your hands with anti-bacterial soap.
2 In a basin, prepare approximately two gallons of hot water
(45-60°C) and 2 ozs of sanitiser equipped (stera sheen green
label).
3 Soak all the parts to be sanitised into the solution for the
amount of time specified by the product manufacturer or for at
list 5 minutes.
4 Allow to dry all sanitised parts in the open air, on a clean
surface.
5 Dry all the external parts of the dispenser without using
abrasive cloths.
5. 4. 4 ASSEMBLY
1 Insert the drip tray back in its seat.
2 Lubricate the tap piston, the scraper fitting and the front of
the scraper in the points indicated in Figure 25 using only the
grease provided with the machine or other grease for foodstuff.
figure 27
3 Reassemble the coupling and the scraper in the reverse
order to disassembly.
4 Reassemble the tap assembly in the reverse order to that
illustrated in Figure 20 and reposition it in its seat.
5 Screw both knobs back on, tightening them carefully.
6 Reassemble the front panel. (see figure 28)
figure 28
7 If present, assemble the magnetic stirrer and the impeller as
shown in figure. (see figure 29)
8 Fit the mixer together taking care to insert the ends in the
grooves in the upper basin.(see figure 30)
9 Replace the float, taking care to respect the orientation
shown in the figure, and the fork attachment.(see figure 31)

5. 4. 5 IN-PLACE SANITIZATION

The sanitising of the assembled appliance prior to
operation should be performed in addition to the sanitising
of the disassembled appliance described herein above, and
never instead of it.
1 Fill a basin with a solution of approximately one gallon of
water and 1 oz of sanitiser equipped (stera sheen green label).
2 Pour the solution into the tank.
3 Using a suitable brush, distribute the solution onto all the
parts above the level of the solution.
4 Fit the cover and operate the dispenser in order to mix the
solution for approximately 5 minutes.
5 Empty the dispenser of the sanitising solution through the
tap, and then eliminate it.
6 Rinse with clean water so as to remove all residue of
sanitising solution from the bottom of the tanks.
7 Do not perform any further rinsing.

6 MAINTENANCE

1 Once a day: check the dispenser and make sure there are
21
figure 29
figure 30
figure 31

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Quick-gel

Inhaltsverzeichnis