not product leaks from the tap assembly seal. If you notice a
leak, check first and foremost that the components have been
assembled correctly, then make sure the seal is not worn or
faulty, in which case replace it with an original spare part from
the manufacturer. (see figure 32)
figure 32
ATTENTION
Before performing any cleaning, always disconnect the
dispenser from the electricity supply by unplugging it.
2 Once weekly: make sure the scraper coupling seal is not
worn. If it is, replace with an original spare part from the
manufacturer. (see figure 33)
figure 33
3 3 Once weekly: check for the presence of any leakage by
removing the purpose-designed tray. If necessary (see figure
34)
figure 34
4 Once a month: eliminate any dust that has built up on the
condenser filter situated at the rear of the machine. (see figure
35)
ATTENTION
Be careful with the condenser fins as they are sharp.
5 In the event of strange noises, disconnect the cooler and
call for assistance.
6 In the event of a breakdown, disconnect the machine as it
may start again suddenly.
7 After all repair work, reposition every component, such as
the screws and covers, in their original position.