Cleaning and Maintenance

8.12 Printing Weighing Result with ID Marking

The device, the sample and a batch can be assigned an ID
number . The ID numbers are exported during GLP-compliant
printing .
Requirements
− The identity number is specified (see Chapter "7 .3 .20
"INPUT" Menu", page 26) .
− The printing of the lot ID line in the GLP printout is
activated in the menu (see Chapter "7 .3 .20 "INPUT" Menu",
page 26) .
− The "SPL . ID" output is activated in the menu .
− The GLP-compliant printout is activated (see Chapter "7 .3 .7
"DATA .OUT ."/"PRNT .PAR ." Menu", page 22) .
Procedure
Start the printout . To do so, press the [Print] button .
t
The GLP header is printed with the ID marking of the
y
LOT ID set in the menu and the current weight value .
The [GLP] button appears in the operating display .
y
Confirm the [PRINT] button .
t
The SPL . ID and the current weight value are exported .
y
Confirm the [PRINT] button .
t
The SPL . ID and the current weight value are exported .
y
To exit the GLP printout: Press the [GLP] button .
t
The GLP footer is printed .
y
9
Cleaning and
Maintenance
9.1
Removing the Weighing Pan and
Associated Components
Requirements
− The device is switched off .
− The device is disconnected from the power supply .
Procedure
30
Entris
®
BCE Operating Instructions
Remove the weighing pan,
t
the shock absorbers and
the frame draft shield .
9.2

Cleaning the Device

NOTICE
Corrosion or damage to the device due to unsuitable
cleaning agents!
Do not use corrosive, chloride-containing, or aggressive
t
cleaning agents .
Do not use cleaning agents that contain abrasive
t
ingredients, e .g . scouring agents, steel wool .
Do not use solvent-based cleaning agents .
t
Only use suitable cleaning agents (materials see Chapter
t
"15 .6 Materials", page 36) and observe the product
information for the cleaning agent used .
Procedure
NOTICE Malfunction or damage to the device due to the
t
ingress of moisture or dust!
Only slightly moisten cleaning materials, such as cloths .
t
Remove dust and powdery sample residue with a brush
t
or hand-held vacuum cleaner .
Wipe the device and the associated components with a
t
slightly damp cloth . Use a mild soapy solution or a suitable
cleaning agent for more severe contaminations .
9.3
Assembling the Weighing Pan and
Associated Components
Procedure
Assemble the weighing pan and the associated components
t
(see Chapter "5 .5 Assembling the Device", page 15) .
Connect the device to the power supply (see Chapter "6 .2
t
Connecting the Power Supply", page 16) .
9.4

Maintenance Schedule

Interval
Component Action
Regularly; depending on
Device
the operating conditions
9.5

Software Update

For a software update, contact Sartorius Service .
Contact Sartorius
Service .