Herunterladen Inhalt Inhalt Diese Seite drucken

PeakTech 4105 Bedienungsanleitung Seite 142

Dds arbitrary waveform generator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.1.6 Amplitude
Amplitude Range: (auto range, offset 0Vdc)
50 Ω load
0.1mVpp to 10Vpp
0.1mVpp to 7.5Vpp
Amplitude Resolution
<1Vpp, 50Ω load
0.1mVpp
Amplitude Accuracy (1kHz Sine, 0V offset, auto range): ±(setting value×1%+1mVpp)
Amplitude Flatness (compared to 100kHz Sine):
Amplitude Unit (Sine): Vpp, Vrms and dBm
7.1.7 Offset (amplitude 0.2mVpp)
Offset range:
50Ω load
open-circuit
Offset resolution:
offset<0.5Vdc, 50Ω load
offset≥0.5Vdc, 50Ω load
offset<1Vdc, open circuit
offset≥1Vdc, open circuit
Offset accuracy: ±(setting value×1%+1mVdc)
≥1Vpp, 50Ω load
1mVpp
<5MHz
<20MHz
≥20MHz
Open-circuit
0.2mVpp to 20Vpp
0.2mVpp to 15Vpp
<2Vpp, open circuit
0.2mVpp
±5Vdc
±10Vdc
0.1mVdc
1mVdc
0.2mVdc
2mVdc
141
Frequency
≤20MHz
>20MHz
≥2Vpp, open circuit
2mVpp
±0.2dBm
±0.3dBm
±0.5dBm

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

4115

Inhaltsverzeichnis