Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance & Fuse Replacement; Specifications - PeakTech 4105 Bedienungsanleitung

Dds arbitrary waveform generator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. Maintenance & fuse replacement
In the case of an electrical defect the melting fuse on the rear side (6) of the device may
trigger.
If this is the case, use only a fuse with the same ratings (T 3A/250V 5x20mm) for
replacement.
In normal operation mode the fuse should never trigger without any reasons, so make sure
the electrical defect is eliminated before restarting the device.
Note: The repair must be performed only by qualified personnel.

7. Specifications

7.1 Continuous Output (CHA&CHB)
7.1.1 Waveform
Standard Waveforms: Sine, Square, Ramp, Pulse, Noise
Built-in Arbitrary: 50 waveforms including PRBS (Pseudorandom Binary Sequence), Exponential Fall,
Exponential Rise, Logarithm, Sinc, Gaussian, Cardiac, Tangent, Semi-Circle, Quake, etc.
User-defined Arbitrary: 5
7.1.2 Spectral Purity of Sine
P 4105:
Harmonic distortion (0dBm): ≤-60dBc Frequency<5MHz
P 4115:
Harmonic distortion (0dBm): ≤-60dBc Frequency<5MHz
Total Distortion (20Hz to 20kHz, 20Vpp): ≤0.1%
≤-50dBc
Frequency≥5MHz
≤-50dBc
Frequency<30MHz
≤-45dBc
Frequency≥30MHz
139

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

4115