Monitoring of the Operation

Fig. 7 - Example of a lubrication system
A - Pressure relief valve
B - Main metering device SSV 6
C - Secondary metering device
SSV 8
D - Secondary metering device
SSV 6
Fig. 8 - Indicator pin installed on metering device
Fig. 9 - Pressure limiting valve
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
1064b02
E - Pressure plastic tube
(dia. 6x1,5 mm)
F - Secondary metering device
SSV 12
G -High pressure hose
(dia. 4.1 x2.3 mm)
1011a96
4092a97

System-dependent monitoring

• The main metering device (B, Fig. 7) and the secondary mete-
ring devices are connected by a main line G. This feature auto-
matically causes the linkage of the progressive system connec-
ted downstream of the pump.
• If only one piston does not move in any metering device or if the
metering device can no longer dispense any lubricant via its
outlets, this metering device will block itself.
• If one of the secondary metering devices is blocked, the main
metering device is also blocked. The whole progressive system
installed downstream of the pump stops operating.
• The fundamental internal structure of the progressive metering
device guarantees the self-monitoring of the sequence within the
metering device.
• The linkage makes it possible to monitor the operation of the
whole system.

Visual monitoring

• The metering devices can be equipped with an indicator pin
which is connected to the piston and moves back and forth du-
ring lubricant distribution.
• If there is a blockage in the system, the indicator pin stops mo-
ving.
Note: It is also possible to indicate the movements of the indicator
pin or any blockage in the system by means of a control switch
(KS) or a proximity switch (KN).
1 – Closure Plug 519-32 123-1
• The whole system can be monitored visually via the pressure li-
miting valve. If lubricant is leaking at the pressure limiting valve
during the distribution sequence, this indicates that there is a
blockage in the system.
Important: In the case of the progressive metering devices models
SSV 6 - 12 and the block-type metering devices SSV 14 through
SSV 22 the outlets 1 and/or 2 must never be closed, otherwise
the system would block owing to the structure of the metering
device.