Herunterladen Inhalt Inhalt Diese Seite drucken

Monitoring Of The Operation; System-Dependent Monitoring; Visual Monitoring - Lincoln Quicklub SSV Benutzerinformation

Progressiv verteiler fuer fett und oel
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
User Manual
Operating Instructions

Monitoring of the Operation

Fig. 22
Example of a lubrication system
F ig. 23
Indicator pin installed on metering device
Page 14 of 24
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Operation, continuation

System-dependent monitoring

The main metering device B (fig. 22) and the secondary
metering devices are connected by a high-pressure
hose G. This feature automatically causes the linkage of
the progressive system connected downstream of the
pump.
If only one piston does not move in any metering device
or if the metering device can no longer dispense any lu-
bricant via its outlets, this metering device will block itself.
If one of the secondary metering devices is blocked, the
main metering device is also blocked. The whole progres-
sive system installed downstream of the pump st ops op-
erating.
The fundamental internal structure of the progressive
metering device guarantees the self-monitoring of the se-
quence within the metering device.
The linkage makes it possible to monit or the operation of
the whole system.
1064b9 5
A - pressure relief valve
B - Main metering device SSV 6
C - Secondary metering device SSV 8
D - Secondary metering device SSV 6 G - High pressure plastic hose

Visual monitoring

The metering devices can be equipped with an indicator
pin which is connected to the piston and moves back and
forth during lubricant distribution.
If there is a blockage in the system, the indicator pin stops
moving.
1011 b96
Components of the control pin tube fitting
Closure plug M 11x1x5 MS, assy. (pos. 1) ......... 519-32123-1
NOTE
It is also possible to electrically check the
movements of the indicator pin or any
blockage in the system by means of a
control switch (KS) or a proximity switch
6001a 02
(KN).
2.2EN-20001-I11
E - Pressure plastic tube
F - Secondary metering
device SSV 12

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Quicklub ssv m

Inhaltsverzeichnis