• Fault: Blockage in the downstream progressive system (continued)
• Cause:
• Metering device blocked
• Fault: Differing lubricant amounts at the lubrication points
• Cause:
• Lubricant metering not correct
• Respective valve body has been assembled without clam-
ping ring
• Setting of the pause time or lubricating time incorrect
• Fault: Over- or underlubrication of the lubrication points
• Cause:
• Setting of the lubricating time or pause time incorrect
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
• Correction:
• Replace the metering device or clean it in accordance with
the following procedure:
• Remove all tube fittings.
• Unscrew the piston closure plugs.
• If possible, try to eject the piston using a smooth drift (Æ
smaller than 6 mm; 0.24 in.).
• Important: The pistons are precision-fitted into the holes.
Mark the pistons with regard to their installation position and
direction after they have been removed. They must not be
exchanged.
• Thoroughly clean the metering device bodies in a fat-dissol-
ving washing agent, blow them through with compressed
air.
• Press free the slant ducts (Ø 1.5 mm; 0.59 in.) at the thread
ends of the piston holes using a pin.
• Clean the metering devices again and blow them through.
• Reassemble the metering devices.
• If copper washers are used, replace them.
• Before the tube fittings are reassembled, the metering de-
vices should be pumped with oil several cycles by means of
a manual pump. Check that the pressure in the metering
device does not exceed 25 bar (362.8 psi).
• If the pressure is higher, replace the metering device.
• Correction:
• Check the lubricant metering acc. to the lubrication chart
• Remove the valve body and install a clamping ring
• Check the time setting. Refer to the corresponding setting in
the respective "Operating Instructions".
• Correction:
• Check the time setting at the control units or printed-circuit
boards. Refer to the corresponding setting in the respective
"Operating Instructions".