Description/Intended Use

The full face masks protect the face and eyes against aggressive
media.
Special goggles are available for users who wear spectacles. A
welder's protective visor is available for retrofitting.
The standard thread connection conforming to EN 148-1 is designed
to fit respirator filters, power assisted filtering devices, self-contained
breathing apparatus and compressed air line breathing apparatus.
Only use certified respiratory apparatus.
The full face masks are masks according to EN 136 Cl. 3 or Cl. 2 and
carry the CE mark. They correspond with NIOSH directives (USA)
and are approved according to AS/NZS 1716 (Australia/New
Zealand).
o
Operating temperature: –30
C to +60
Use
Keep the full face mask ready
• Loosen the straps as far as possible (figure B).
• Pass the neckband around your neck and button it into the front
strap.
Fasten full face mask
WARNING!
Facial hair under the mask seal can cause leaks.
The mask should not be used by people with
beards and sideburns.
The bow of glasses under the mask seal also
causes leaks. A spectacle frame should be used in
such cases.
16
o
C.
• Check the full face mask to ensure that the head strap is securely
fastened, that the nose cup and the exhalation valve cover are
correctly and that all other parts are in good condition.
• If fitted, push spectacle frame into the desired position.
• Remove neckband.
• Loosen the straps as far as possible (figure B).
• Spread the head strap, place chin in recess (figure C), center the
head strap on the head. Make sure that the head strap rests flush
against the head.
• Make sure that neither hair nor head strap impair the sealing frame,
that the sealing frame contacts the face evenly and adjusts to its
contours.
• First, tighten both neckbands (figure D, step 1), then tighten the
temple straps (figure D, step 2) evenly towards the back of the
head so that the middle of the head strap remains on the middle of
the head (figure E).
• Only tighten the front strap (figure D, step 3) if required. Breathe
normally.
Spent air should leave the exhalation valve easily.
• Check for leaks:
— Tightly compress the mask connection and breathe in until a vac-
uum is produced.
— Briefly hold your breath: the vacuum must be maintained. If it is
not, the head strap must be tightened further.
— The leak test must be repeated twice.
WARNING!
The mask should only be used if perfectly tight,
otherwise there is danger of poisoning!