Description
2.1

Product overview

6
5
4
3
2
1
12
11
1
Connector
2
Control valve
3
Inner mask
4
Visor
5
Visor frame
6
Upper head-harness
connector
14
7
8
9
10
7
Harness
8
Face seal
9
Carrying strap
10 Mask body
11 Clamping ring
12 Exhalation valve cover
(approved by Dekra Exam)
2.2

Feature description

The full face masks have a universal connector (M 45×3 screw
connection) compliant with DIN EN 148-3. This makes the full face
masks suitable for overpressure self-contained breathing apparatuses
and overpressure airline equipment.
The full face masks can be used at temperatures from –30 °C to
+60 °C.
Mask spectacles can be inserted for users who wear spectacles.
2.3

Intended use

The full face masks protect the face and eyes against aggressive
media.
2.4

Limitations on use

WARNING
!
Beards and sideburns in the sealing area of the full face mask
will cause leakages! Therefore the full face mask should not
be used by anyone with facial hair of this sort. Earpieces in
the sealing area also cause leakages. Use special mask
spectacles.