Replacing the inhalation valve disc
• Pull the inhalation valve out by its tab.
• Remove the old valve disc and fit new disc.
• Press the inhalation valve into the mask connector until it makes
even contact all-round. The valve disc must not be pinched. The
disc must face inwards, and the stems face outwards.

Storage

• Undo the straps as far as possible.
• Wipe lens with antistatic cloth.
• Pack full face mask in its bag or box.
• Store it in a dry, dust-free place where it is not deformed.
o
Storage temperature: –10
C to 60
Keep out of direct sunlight and heat.
Observe ISO 2230 "Rubber Products - Guidelines for Storage" and
national guidelines for storage, maintenance and cleaning of rubber
products.
o
C.

Test and Maintenance Intervals

Work to do
Cleaning and disinfection
Visually inspect, check correct
function and leak-proofing
Replace exhalation valve disc
Replace speech diaphragm
Check by wearer
1)
gastight packed full face masks, otherwise every 6 months
2)
gastight packed full face masks every 2 years
1)
X
X
2)
X
X
X
X
X