Description
27
Spring holder
1)
Available in red, black or grey.
Despite different versions, operation is always the same.
3.2

Feature description

The Dräger FPS 7000 facepieces are available in the following various
versions:
as full face mask (consisting of mask body with harness connecting piece
and head harness. An elastic strap or a hairnet can be used as a head
harness.)
as mask/helmet combination (consisting of mask body without harness
connecting piece, with mask/helmet adapter and associated helmet)
The facepieces are designed as follows:
RA
Round-thread connector RD40x1/7" according to EN 148-1 for respira-
tory filters, powered air purifying respirators, SCBAs or airline equip-
ment
PE
Threaded connection M45x3 according to EN 148-3 for SCBAs or air-
line equipment
ESA Standard plug-in connector according to DIN 58600 for SCBAs and air-
line equipment (and respiratory filters according to EN 14387)
P
Plug-in connector (Dräger-specific) for SCBAs or airline equipment
Notice for ESA-type connectors
Exhalation resistances do not comply with EN 136 if respiratory filters with
round-thread connectors according to DIN EN 148-1 are used. Normal-
pressure SCBAs or normal-pressure airline equipment must not be connected
to this thread.
The facepieces can be used at temperatures from –30 °C to +60 °C.
Mask spectacles can be inserted for users who wear spectacles.
16
28
Spring
3.3

Intended use

The facepieces protect the face and eyes from aggressive media.
3.4

Limitations on use

WARNING
Beards and sideburns in the sealing area of the full face mask will cause
leakages. Therefore, the full face mask should not be used by anyone with
facial hair of this sort. Earpieces in the sealing area also cause leakages.
► Use special mask spectacles.
3.5

Approvals

The full face masks are approved according to:
EN 136:1998 CL.3+
(EU) 2016/425
(EU) 2016/425 as brought into UK law and amended
The mask/helmet combinations are also approved according to:
DIN 58610:2014
Declarations of conformity: see www.draeger.com/product-certificates
Both versions meet the flame engulfment requirements stipulated in
EN 137:2006.
Dräger FPS 7000 P and Dräger FPS 7000 RA facepieces comply with the U.S.
NIOSH regulations.
Dräger FPS 7000 RA facepieces are approved according to
AS/NZS 1716:2012 in Australia and New Zealand.
NOTICE
Full face masks must not be retrofitted to a mask-helmet combination.
The facepieces may only be used with approved SCBAs, powered air purifying
respirators, airline equipment or respiratory filters.
Instructions for use
|