• Checking the exhalation valve:
— Seal the mask connector and exhale vigourously.
The exhaled air must escape easily, otherwise see "Visual inspec-
tion of exhalation valve" on page 19.
• Connect the compressed air breathing apparatus, power assisted
filtering device, fresh air hose breathing apparatus or breathing
1)
filter
.
Operation with breathing filters
Requirements
— Europe, with the exception of the Netherlands: The ambient air
must contain at least 17 % oxygen.
Netherlands: The ambient air must contain at least 19 % oxygen.
USA: The ambient air must contain at least 19.5 % oxygen.
— Observe national regulations.
— Not ventilated containers, cavities, channels etc. may not be en-
tered with the filter apparatus.
— The type of pollutants must be known, chose corresponding
breathing filter.
Screw in the breathing filter
• Entirely remove the sealing strip and firmly screw in the breathing
filter clockwise.
Operating period
The operating period depends on various factors, including the type
and concentration of pollutant and the type of filter.
1)
Note the corresponding Instructions for Use.

Extreme operating conditions

Low temperatures
• Treat lens with antimisting agent "klar-pilot" Gel
fogging up.
• Exhalation valve disc may harden. Check leaktightness of
exhalation valve disc.
High temperatures
Leave the danger zone immediately if lens is damaged.
Potentially explosive atmospheres
• Treat the mask with antistatic spray or work with a screen of water
mist.

After Use

• Remove respirator filter, breathing apparatus and/or connection
tube of the power assisted filtering device or fresh air hose
1)
breathing apparatus
.
• Dispose of the respirator filter
• Remove full face mask:
Slide your index finger under the ends of the neck straps, press the
clamps of the head harness forwards with your thumbs to loosen
them (figure F). Pull the full face mask up and away from the face
over the head.
WARNING!
Do not take hold of the full face mask's connection
piece, as this could damage the mask and/or
contaminate the equipment wearer.
1)
to prevent it from
1)
.