Herunterladen Inhalt Inhalt Diese Seite drucken

For Your Safety - Dräger X-plore 6300 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für X-plore 6300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Table of Contents

For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Safety Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
What is What (Figure A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Description/Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
After Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Cleaning and Disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Special Maintenance Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Test and Maintenance Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Order List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
14
For Your Safety
Strictly follow the Instructions for Use.
Any use of the full face mask requires full understanding and strict
observation of these instructions. The full face mask is only to be
used for the purposes specified herein.
Maintenance
The full face mask must be inspected and serviced by experts at regu-
lar intervals and a record kept.
Repair and general overhaul of the full face mask may only be carried
out by trained service personnel.
We recommend signing a service contract with Dräger Safety to have
all maintenance jobs carried out.
Only authentic Dräger spare parts may be used for maintenance.
Observe chapter "Maintenance Intervals".
Be sure to read the information contained in the chapter "Mainte-
nance Intervals".
Liability for proper function or damage
The liability for the proper function of the full face mask is irrevocably
transferred to the owner or operator to the extent that the full face
mask is serviced or repaired by personnel not employed or authorized
by Dräger Safety or if the full face mask is used in a manner not con-
forming to its intended use.
Dräger Safety cannot be held responsible for damage caused by non-
compliance with the recommendations given above.
The warranty and liability provisions of the terms of sale and delivery
of Dräger Safety are likewise not modified by the recommendations
given above.