Fig.E1
CAUTION! Do not force the lower tube into the powerhead! Excessive force can damage the
components.
4.2- Connecting the throttle cable
1. Remove the air cleaner cover
2. Connect the end of the throttle cable to the joint on the top of the carburetor. See Fig.E3, Fig.E4
4.3- Connecting Switch Wires
Connect the switch wires between the engine and the main unit.
Pair the wires of the same color. See Fig.E5
Fig.E3
4.4- Adjusting the Throttle Cable
1. Loosen the throttle cable nut at fan cover as shown in Fig.E6
2. Adjust the throttle cable adjuster nuts until you achieve a free play on the throttle trigger of about
6mm. See Fig.E7.
3. When 6mm free play is achieved, tighten the two 10mm throttle cable nuts.
When the throttle cable is correctly adjusted, and the throttle trigger is fully depressed (full throttle),
the throttle will contact the stop on the throttle body. See Fig.E8
4. Replace the air cleaner cover
Fig.E2
Fig.E4
Fig.E2
1. Throttle cable
2. Lower tube
3. Main shaft
4. Tube clamp
5. Clamp screw
Fig.E5