Troubleshooting
Symptom
The pedaling monitor sensor in
the power meter mode cannot
pair to a different company's
cyclocomputer.
The red LEDs light for 10
seconds when batteries are
inserted.
Calibration
Symptom
Zero point calibration fails.
Zero point calibration does not
finish.
The force preview is not near 0
N after calibrating the zero point
in pedaling monitor mode.
Zero point calibration fails in
power meter mode.
28
Cause
The other company's
cyclocomputer does not
support ANT+ power meter.
The pairing of the left and right
sensors failed.
Something is wrong with the
strain gauge unit.
The circuit board in the
transmitter is broken.
There is something wrong with
the circuit board of the junction
box or junction cable for the
right sensor.
Cause
There are loads on the cranks or
pedals.
Water inside the sensors.
Something is wrong with the
strain gauge unit.
The circuit board in the
transmitter is broken.
There is something wrong with
the circuit board of the junction
box or junction cable for the right
sensor.
The sensor and Cyclocomputer
pairings are not stable.
There are loads on the cranks or
pedals.
There are loads on the cranks or
pedals.
This is a problem with either the
left or right sensor.
User
Check that the Cyclocomputer being used supports pairing with the ANT+
power meter.
If it does, check the sensor operation mode. If the sensor is in the pedaling
monitor mode, set it to the power meter mode and connect it.
When the sensor is connected to another brand of Cyclocomputer, total power
and left/right balance can be displayed. Applied forces and pedal direction at
each rotation angle, and left/right pedaling efficiency cannot be displayed. For
more information about this type of configuration, refer to the other brand of
Cyclocomputer's user documentation.
Press the right transmitter switch and check the sensor operation mode. After
confirming that the left/right LEDs light orange, connect the sensor to the
Cyclocomputer. If the LEDs do not light orange, change the operation mode.
After you load batteries, the sensors start in the pedaling monitor mode.
Contact your dealer.
User
Stop the bicycle, remove any load from the cranks and pedals, and then calibrate it.
It may fail if a load is applied.
Water can get into the sensors when the right transmitter cover and/or the left
transmitter battery cover are not attached correctly. Remove the batteries. After the
interior of the sensors are sufficiently dry, perform zero point calibration again.
Contact your dealer.
Information may not be sent correctly to the sensor depending on the radio wave
environment and the distance between the Cyclocomputer and the sensor. Stop the
zero point calibration and move the Cyclocomputer closer to the sensor or do the
calibration again in a location with a better radio wave environment.
Stop the bicycle, remove any load from the cranks and pedals, and then calibrate it.
The zero point may be incorrect if a load is applied.
Position either the left or right crank at 6 o'clock before calibrating from the
Cyclocomputer. For more information about calibration, refer to the other brand of
Cyclocomputer's user documentation.
Check that there are no loads on either the left or right cranks or pedals.
Calibration fails if there is a load on either the left or right cranks or pedals, because
the left and right zero point is calibrated at the same time for the power meter
mode.
Contact your dealer.
Solution
Dealer
Please visit our website.
Solution
Dealer
Please visit our website.
The zero point calibrations are done at
the same time for the power meter mode.
The zero point calibrations may fail if
either the left or right sensor is faulty.
Please visit our website.