Error codes

An error code is displayed if an error occurs while setting the crank length or doing calibrations.
Code
Description of error
1
Parameter deviation (mass of load is 0)
2
Insufficient battery power
3
Failed to calibrate zero point (tangential and radial)
4
The zero point calibration is very different from the desired
value.
5
Not used
6
Large disruption detected due to vibration during calibration
7
Calibration with load was done before high accuracy zero point
calibration
8
Exceeded measurement limit during load calibration
Data (radial)
-
-
1: Error
0: Normal
Multiple of detected value of force Multiple of detected value of force
-
Degree of instability of detected
value of force
-
Multiple of detected value of force Multiple of detected value of force
Troubleshooting
Data (tangential)
-
-
1: Error
0: Normal
-
Degree of instability of detected
value of force
-
EN